OF, THE MATERIAL. Trademarks Ruckus Wireless , Ruckus , the bark logo, ZoneFlex , FlexMaster , ZoneDirector , SmartMesh , Channelfly , Smartcell , Dynamic PSK , and Simply Better Wireless are trademarks of Ruckus Wireless, Inc. in the United States and other countries. All other product or company names may be trademarks of their respective owners.
Most user guides and release notes are available in Adobe Acrobat Reader Portable Document Format (PDF) or HTML on the Ruckus Wireless Support Web site at https://support.ruckuswireless.com/contact-us.
International Mobile Subscriber Identity Location Services Mobile Application Part MSISDN Mobile Subscriber Integrated Services Digital Network Number Message Single Unit Media Termination Point MWSG Metro Wireless Security Gateway Originating Point Code Ruckus Wireless SmartCell Gateway 200 HLR Interface Reference Guide for SmartZone 3.5.1...
For a complete list of documents that accompany this release, refer to the Release Notes. Online Training Resources To access a variety of online Ruckus Wireless training modules, including free introductory courses to wireless networking essentials, site surveys, and Ruckus Wireless products, visit the Ruckus Wireless Training Portal at: https://training.ruckuswireless.com.
Documentation Feedback Ruckus Wireless is interested in improving its documentation and welcomes your comments and suggestions. You can email your comments to Ruckus Wireless at: docs@ruckuswireless.com When contacting us, please include the following information: • Document title • Document part number (on the cover page) •...
STP (Signal Transfer Point) based on the configuration settings in the user interface. It is not mandatory that the SCG connects to HLR through STP. The SCG allows for a direct connection. Ruckus Wireless SmartCell Gateway 200 HLR Interface Reference Guide for SmartZone...
Page 11
This guide does not provide design details of either the SCG or HLR for handling interface requirements. NOTE Refer to About this Guide on page 5 for the conventions used in this guide. Ruckus Wireless SmartCell Gateway 200 HLR Interface Reference Guide for SmartZone 3.5.1...
MAP version 3. The value of this attribute will be sent only if the EAP-SIM version is set to 3 while configuring the HLR service profile in the SCG Web interface. Ruckus Wireless SmartCell Gateway 200 HLR Interface Reference Guide for SmartZone 3.5.1...
Error messages are based on the following failure reasons: • Unknown subscriber • Unexpected data value • System failure • Data missing Ruckus Wireless SmartCell Gateway 200 HLR Interface Reference Guide for SmartZone 3.5.1...
(IMSI) of the subscriber. value SGSN Number Variable This attribute is the ISDN number of SGSN. SGSN Address Variable This attribute is the IP address of the SCG node. Ruckus Wireless SmartCell Gateway 200 HLR Interface Reference Guide for SmartZone 3.5.1...
Error messages are based on the following failure reasons. • Unknown subscriber • Unexpected data value • System failure • Data missing Ruckus Wireless SmartCell Gateway 200 HLR Interface Reference Guide for SmartZone 3.5.1...
Octet String This parameter indicates the address (16) of the data protocol. QoS Subscribed Octet String This parameter indicates the quality of service subscribed for a certain service. Ruckus Wireless SmartCell Gateway 200 HLR Interface Reference Guide for SmartZone 3.5.1...
The parameter is supplied by the MAP service-user and is unique for each service-user/service-provider interface. IMSI Maximum 15 International Mobile Subscriber digit value Identity (IMSI) of the subscriber. Ruckus Wireless SmartCell Gateway 200 HLR Interface Reference Guide for SmartZone 3.5.1...
The user data session will be deleted if the SCG receives this attribute as subscription Withdraw(1) or updateProcedure(0). This attribute is mandatory for the SCG to process the cancellation procedure. Ruckus Wireless SmartCell Gateway 200 HLR Interface Reference Guide for SmartZone 3.5.1...
User error Integer This attribute is triggered in case of failure to cancel the subscriber from HLR. The following error messages are displayed: • Unidentified subscriber • Data missing Ruckus Wireless SmartCell Gateway 200 HLR Interface Reference Guide for SmartZone 3.5.1...
This attribute is triggered in case of failure to delete the subscriber from HLR. The error message is displayed, when the IMSI subscriber is not found is, Unidentified subscriber. Ruckus Wireless SmartCell Gateway 200 HLR Interface Reference Guide for SmartZone 3.5.1...
The contents of each element are either one value (primitive) or one or more information elements (constructor), as seen in Figure 2: TCAP messages on page 22 below. Figure 2: TCAP messages Ruckus Wireless SmartCell Gateway 200 HLR Interface Reference Guide for SmartZone 3.5.1...
Application Context Variable The application context is the identifier Name of the application context, which is proposed by the dialogue initiator or by the dialogue responder Ruckus Wireless SmartCell Gateway 200 HLR Interface Reference Guide for SmartZone 3.5.1...
Page 24
56 for SendAuthenticationInfo and 23 for UpdateGPRSLocation. Parameter Variable This attribute indicates the sequence tag. This can either be a primitive/constructor and can contain multiple parameters. Ruckus Wireless SmartCell Gateway 200 HLR Interface Reference Guide for SmartZone 3.5.1...
This attribute identifies an operation invocation and its result. Operation Code Variable This attribute indicates the local operation code such as 56 for SendAuthenticationInfo and 23 for UpdateGPRSLocation. Ruckus Wireless SmartCell Gateway 200 HLR Interface Reference Guide for SmartZone 3.5.1...
Application Context Variable The application context is the identifier Name of the application context, proposed by the dialogue initiator or by the dialogue responder. Ruckus Wireless SmartCell Gateway 200 HLR Interface Reference Guide for SmartZone 3.5.1...
Attribute is optional. Mandatory if the attribute is present. This attribute should not be present in RestoreData response message (second continue) but should be present in the RestoreData request message. Ruckus Wireless SmartCell Gateway 200 HLR Interface Reference Guide for SmartZone 3.5.1...
Page 28
This attribute indicates the local operation code and restore data. Parameter Variable This attribute indicates the sequence tag. This can either be primitive/constructor and can contain multiple parameters. Ruckus Wireless SmartCell Gateway 200 HLR Interface Reference Guide for SmartZone 3.5.1...
29. It could consist of one or a combination of the following elements. • Signaling point code • Global title (example, dialed digits) • Subsystem number Figure 3: Address indicator Ruckus Wireless SmartCell Gateway 200 HLR Interface Reference Guide for SmartZone 3.5.1...
Nature of Address, Translation Type, Numbering Plan and Encoding scheme parameters are included. Since GTI value is 0010, only translation type is shown in the example. Ruckus Wireless SmartCell Gateway 200 HLR Interface Reference Guide for SmartZone 3.5.1...
Variable This attribute can have a total >=3 octets. Indicator It indicates the address type information contained in the address field. Refer to Address Indicator on page 29. Ruckus Wireless SmartCell Gateway 200 HLR Interface Reference Guide for SmartZone 3.5.1...
Page 32
XUDT message Importance Variable This attribute Indicate the importance of the messages. End of Optional Octet This attribute consists of a single octet Parameter containing all zeros. Ruckus Wireless SmartCell Gateway 200 HLR Interface Reference Guide for SmartZone 3.5.1...
Figure 4: Message Signal Unit MTP3 message structure applies to all MAP messages that are using the SS7 interface. Table 25: MTP3 message structure on page 34 lists the attributes for MTP3. Ruckus Wireless SmartCell Gateway 200 HLR Interface Reference Guide for SmartZone 3.5.1...
Page 34
• 4-bit service indicator field Routing Label Variable Routing label consists of DPC, OPC and User Message Variable This attribute contains signaling data (for SCCP, TCAP and MAP). Ruckus Wireless SmartCell Gateway 200 HLR Interface Reference Guide for SmartZone 3.5.1...
Checksum Variable This attribute contains the checksum of the SCTP packet. Chunk Type 0 to 254 This attribute identifies the type of information contained in the chunk value. Ruckus Wireless SmartCell Gateway 200 HLR Interface Reference Guide for SmartZone 3.5.1...
Page 37
This attribute identifies the stream to which the user data belongs. Stream Sequence 0 to 65535 This attribute value represents the Number stream sequence number of the user data within the stream. Ruckus Wireless SmartCell Gateway 200 HLR Interface Reference Guide for SmartZone 3.5.1...
SCTP destination port, and possibly the destination IP address to identify the association to which this packet belongs. NOTE Port number 0 should not be used. Ruckus Wireless SmartCell Gateway 200 HLR Interface Reference Guide for SmartZone 3.5.1...
Page 39
An endpoint sends this chunk to its peer endpoint as a response to a HEARTBEAT chunk. Heartbeat Acknowledge message format is as shown in Table 28: Heartbeat Acknowledgment Message (HEARTBEAT ACK) attributes on page 40. Ruckus Wireless SmartCell Gateway 200 HLR Interface Reference Guide for SmartZone 3.5.1...
Page 40
Information field. Heartbeat Variable This field must contain the Heartbeat Information Request to which this Heartbeat acknowledgment responds. Ruckus Wireless SmartCell Gateway 200 HLR Interface Reference Guide for SmartZone 3.5.1...
Variable This attribute contains the original SS7 MTP3 message, including the Service Information Octet and Routing Label. OPC is from the routing label of the original SS7 message. Ruckus Wireless SmartCell Gateway 200 HLR Interface Reference Guide for SmartZone 3.5.1...
Page 42
SLS bits from the routing label of the original SS7 message. User Protocol Data Variable User Protocol Data contains an octet string of MTP-User information from the original SS7 message. Correlation ID Variable Ruckus Wireless SmartCell Gateway 200 HLR Interface Reference Guide for SmartZone 3.5.1...
M3UA Heartbeat Message The BEAT message is optionally used to ensure that the M3UA peers are still available to each other. The BEAT Ack message is sent in response to a received BEAT message. It includes all the parameters of the received BEAT message, without any change. Table 30: M3UA Heartbeat Message structure on page 43 lists the BEAT attributes.
Page 44
Global title indicator MAP_UPDATE_GPRS_LOCATION Request Global Title Indicator – Translation Type 30–31 MAP_UPDATE_GPRS_LOCATION Response GPRS Subscription Data MAP-INSERT-SUBSCRIBER-DATA Request GPRS Subscription Data Withdraw MAP-INSERT-SUBSCRIBER-DATA request attributes MAP-INSERT-SUBSCRIBER-DATA Request/Response Ruckus Wireless SmartCell Gateway 200 HLR Interface Reference Guide for SmartZone 3.5.1...
Need help?
Do you have a question about the SCG-200 and is the answer not in the manual?