Servicing The Storage Backplanes; Remove A Storage Backplane - Oracle SPARC T5-4 Service Manual

Hide thumbs Also See for SPARC T5-4:
Table of Contents

Advertisement

Servicing the Storage Backplanes

For the location of the storage backplanes, see
This procedure requires that you handle components that are sensitive to electrostatic
Caution -
discharge. This discharge can cause failure of server components.
"Remove a Storage Backplane" on page 107
"Install a Storage Backplane" on page 111

Remove a Storage Backplane

A storage backplane is a cold-service component that can be replaced only by authorized
service personnel.
This procedure requires that you handle components that are sensitive to electrostatic
Caution -
discharge. This discharge can cause failure of server components.
1.
Power off the server.
See
"Removing Power From the Server" on page
2.
Remove all the hard drives from the front of the server for the storage backplane
that you want to replace.
Note the locations of the drives before removing them so that you can install them later in their
original slots. You have to remove only hard drives 0–3 or drives 4–7, depending on which
storage backplane you want to replace. See
3.
Remove the main module from the server.
See
"Remove the Main Module" on page
Take the necessary ESD precautions.
4.
See
"Prevent ESD Damage" on page
"Processor Module Components" on page
51.
"Remove a Hard Drive" on page
99.
54.