Determine Which DIMM is Faulty (PSH)
1.
Start the Fault Management Shell:
->
start /SP/faultmgmt/shell
Are you sure you want to start /SP/faultmgmt/shell (y/n)?
Type:
2.
fmadm faulty
faultmgmtsp>
------------------- ------------------------------------ -------------- ------
Time
UUID
------------------- ------------------------------------ -------------- ------
2013-01-18/21:04:40 7040d859-5b03-4a58-8dfd-e3a80875d62f SPSUN4V-8000-EJ Critical
Problem Status
: solved
Diag Engine
: fdd 1.0
System
Manufacturer
: Oracle Corporation
Name
: SPARC T5-4
Part_Number
: 7021179
Serial_Number : 1201CTHC01
System Component
Manufacturer
: Oracle Corporation
Name
: SPARC T5-4
Part_Number
: 7021179
Serial_Number : 1201CTHC01
----------------------------------------
Suspect 1 of 1
Fault class : fault.memory.dimm-ue
Certainty
: 100%
Affects
: /SYS/PM0/CM1/CMP/BOB0/CH0/D0
Status
: faulted but still in service
FRU
Status
Location
Manufacturer
Name
Part_Number
Revision
Serial_Number
Chassis
Manufacturer
Name
Part_Number
Serial_Number : 1201CTHC01
Description : Uncorrectable errors have occurred while accessing memory.
Response
: An attempt will be made to remove the affected memory from
service. Host HW may restart.
Impact
: Total system memory capacity has been reduced and some
applications may have been terminated.
Action
: Use 'fmadm faulty' to provide a more detailed view of this
event. Please refer to the associated reference document at
http://support.oracle.com/msg/SPSUN4V-8000-EJ for the latest
service procedures and policies regarding this diagnosis.
74
SPARC T5-4 Server Service Manual • July 2016
: faulty
: /SYS/PM0/CM1/CMP/BOB0/CH0/D0
: Samsung
: 8192MB DDR3 SDRAM DIMM
: 07042208,M393B1K70DH0-YK0
: 04
: 00CE0212153367DD4B
: Oracle Corporation
: SPARC T5-4
: 7021179
y
msgid
Severity
Need help?
Do you have a question about the SPARC T5-4 and is the answer not in the manual?
Questions and answers