Oracle SPARC T5-4 Service Manual page 95

Hide thumbs Also See for SPARC T5-4:
Table of Contents

Advertisement

5.
Verify that the blue Ready-to-Remove LED is no longer lit on the drive that you
installed.
See
"Hard Drive LEDs" on page
6.
At the Oracle Solaris prompt, type the cfgadm -al command to list all drives in the
device tree, including any drives that are not configured:
cfgadm -al
#
The replacement drive is now listed as configured. Example:
Ap_id                       Type
...
c2                          scsi-sas     connected    configured      unknown
c2::w5000cca00a76d1f5,0     disk-path    connected
c3                          scsi-sas     connected    configured      unknown
c3::w5000cca00a772bd1,0     disk-path    connected    configured      unknown
c4                          scsi-sas     connected    configured      unknown
c4::w5000cca00a59b0a9,0     disk-path    connected    configured      unknown
...
Perform one of the following tasks based on your verification results:
7.
If the previous steps did not verify the drive, see
Process" on page
If the previous steps indicate that the drive is functioning properly, perform
the tasks required to configure the drive. These tasks are covered in the
Oracle Solaris OS administration documentation.
For additional drive verification, you can run the Oracle VTS software. Refer to the Oracle VTS
documentation for details.
Related Information
"Determine Which Hard Drive Is Faulty" on page 90
"Remove a Hard Drive" on page 90
"Install a Hard Drive" on page 93
89.
Receptacle
Occupant
configured     unknown
23.
   Condition
"Diagnostics
Servicing Hard Drives
Verify the Hard Drive
95

Advertisement

Table of Contents
loading

Table of Contents