Some PCIe cards require a PCIe card carrier extension to ensure proper system
Note -
cooling. If your PCIe card requires a PCIe carrier extension, see
Extension" on page
1.
Insert the PCIe card carrier into the card cage until it stops.
Do not press on the PCIe back panel, or force the PCIe card carrier into the card cage.
Caution -
2.
Close the PCIe carrier handle.
Rotate the handle up until it latches into place.
3.
Connect the cables to the PCIe card.
4.
Determine your next step:
If you replaced or installed a PCIe card in a server that is running (that is, if
■
you hot-serviced the PCIe card), go to
If you replaced or installed a PCIe card in a powered-down server, power
■
on the server using the instructions provided in
Operation" on page
Take the PCIe card online. Do one of the following:
5.
■
Press the ATTN button. The PCIe card carrier's Power OK LED should light,
indicating that the PCIe card is online. Go to
167.
191, then go to
"Install a PCIe Carrier
Step
5.
"Returning the Server to
Step
6.
Step
6.
Servicing PCIe Cards
Install a PCIe Card Carrier
169
Need help?
Do you have a question about the SPARC T5-4 and is the answer not in the manual?
Questions and answers