Servicing the Front I/O Assembly
These topics describe service procedures for the front I/O assembly in the server.
Caution -
discharge. This discharge can cause failure of server components.
"Front I/O Assembly Reference" on page 131
■
"Remove the Front I/O Assembly" on page 131
■
"Install the Front I/O Assembly" on page 133
■
Front I/O Assembly Reference
The front I/O assembly consists of the following components:
Two circuit boards (FIO and VGA boards)
■
A ribbon cable connecting the front I/O assembly to the motherboard
■
Related Information
"Remove the Front I/O Assembly" on page 131
■
"Install the Front I/O Assembly" on page 133
■
Remove the Front I/O Assembly
The front I/O assembly is a cold-service component that can be replaced only by
authorized service personnel. For the location of this component, see
Components" on page
Caution -
discharge. This discharge can cause electronic components to fail.
This procedure requires that you handle components that are sensitive to electrostatic
19.
This procedure requires that you handle components that are sensitive to electrostatic
"Main Module
Servicing the Front I/O Assembly
131