Install a DIMM
DIMMs are cold-service components that can be replaced by customers. For the location of the
DIMMs, see
This procedure requires that you handle components that are sensitive to electrostatic
Caution -
discharge. This discharge can cause failure of server components.
1.
Consider your first steps:
Familiarize yourself with DIMM configuration rules.
■
See
"DIMM Population Rules" on page 69
Prepare the system for service.
■
See
"Preparing for Service" on page
Remove the processor module. Place the processor module on an ESD-protected work
■
surface.
See
"Remove a Processor Module or Processor Filler Module" on page
2.
Consider your next steps:
■
If you are replacing a faulty DIMM, ensure that you have removed the faulty
DIMM.
See
"Remove a DIMM or DIMM Filler Panel" on page
If you are populating a new processor module, ensure you have the correct
■
DIMMs for your server.
See
"DIMM Population Rules" on page 69
If you ordered processor modules without memory to upgrade the server from a single-
Note -
module configuration to a dual-module configuration, you must install DIMMs of the same type
and capacity that are already in the existing processor modules.
"Processor Module Components" on page
18.
45.
77.
Install a DIMM
61.
Servicing DIMMs
79