DIMM Configuration Errors
If the show faulty command reports a fault with a UUID, go on to
not report a fault with a UUID, you are done with the verification process.
7.
Switch to the system console and type the fmadm repaired commandwith the
UUID.
Use the same UUID that was displayed from the output of the Oracle ILOM show faulty
command.
fmadm repaired /SYS/PM0/CMP0/BOB0/CH1/D0
#
Related Information
"DIMM Population Rules" on page 69
■
"DIMM Addresses" on page 70
■
"Determine Which DIMM Is Faulty (DIMM Fault Remind Button)" on page 75
■
"Determine Which DIMM is Faulty (PSH)" on page 73
■
"Remove a DIMM or DIMM Filler Panel" on page 77
■
"Install a DIMM" on page 79
■
"DIMM Fault Handling" on page 73
■
"DIMM Configuration Errors" on page 84
■
DIMM Configuration Errors
When the system boots, system firmware checks the memory configuration against the rules
described in
detected, the following general error message is displayed.
Please refer to the service documentation for supported memory
configurations.
In some cases, the server boots in a degraded state, and a message such as the following is
displayed:
NOTICE: /SYS/PM0/CM0/CMP/CORE8/P0 is degraded
In other cases, the configuration error is fatal, and the following message is displayed:
Fatal configuration error - forcing power-down
84
SPARC T5-4 Server Service Manual • July 2016
"DIMM Population Rules" on page
Step
7. If show faulty does
69. If any violations of these rules are
Need help?
Do you have a question about the SPARC T5-4 and is the answer not in the manual?
Questions and answers