Firmware History for B003/B004/B006/B007
Version
04.00.00
G4 reception failure
Power on failure
Subst. reception file
cannot be printed out
C. code (Korea)
05.00.00
Connecting with
eCabinet
Error report cannot be
printed out
For China
06.00.01
PABX access
Print label insertion list
Power failure report
Standard Message
Stamp
FCU freezes
07.00.00
Printing of the Memory
Storage Report stopped
Power Failure Report
Signal level for the tone
of the A.I. short protocol
Bit Switch default values
Communication LED
CÓPIA NÃO CONTROLADA
Title
Communication failure (receiver time out) sometimes occurs
with G4 reception.
The fax option sometimes does not start up when the main
power is turned on.
Documents received in substitute reception are successfully
stored into SAF memory, however if the main controller goes
into Energy Saver mode during reception, the files cannot be
printed out later.
Country code "1C" for Korea has been enabled.
Modified to enable connection with eCabinet.
When 9 or more error codes are registered in memory, the
error report cannot be printed out.
< China model program segment added >.
Even if the prefix number access mode (Loop start) is selected
in PABX mode, the machine will always select Grand Start
mode. As a result, the prefix number is not sent out to the
telephone line.
When the label insertion list is printed, characters containing
umlauts come out scrambled.
Only the first Substitute Report file appears on the Power
Failure Report.
Even if the language is changed, the standard message is still
stamped in English.
If the modem CPU is performing a total RAM check (as when
one of its RAM contains a certain address value), the FCU
cannot communicate with the modem CPU and freezes.
The software has been changed so that the modem CPU does
not perform the total RAM check.
If the handset is picked up while the Memory Storage Report is
being printed out, the job is stopped and cannot be resumed.
When printing out the Power Failure Report onto 2 pages, and
the machine runs out of paper before printing the second page,
this page cannot be printed out even after reloading more
paper into the machine.
This signal level was set about 1dBm too high, and has been
corrected.
The default values of Bit Sw SYS04 (SP 1-101-005) bits 6 and
7 for Czech/Poland/Hungary have been changed to conform
with PTT requirements.
Bit 6: G3 CSI/G4 Terminal ID programming
Bit 7: Telephone line type programming
The Communication LED remains lit even when the telephone
line is disconnected.
CÓPIA NÃO CONTROLADA
Symptom Corrected