Siemens SIMOTRAS 6SG7050 Operating Instructions Manual page 598

6sg70 series
Table of Contents

Advertisement

Appendix
Term. 81/82 (MB .. ready message)
Term. 83/84 (ST .. setpoint in controlled
Term. 85/86 (BR .. n ≥ n_min)
Term. 87/88 (S1 .. rotor contactor stage 1)
Term. 89/92 (S2 .. rotor contactor stage 2)
Term. 90/92 (S3 .. rotor contactor stage 3)
Term. 91/92 (S4 .. rotor contactor stage 4)
Term. 11/22 (MW .. message "temperature
Potentiometer on SIMOTRAS HE
(6GA4625 series)
TF – Delayed enable
TZ – Brake application time monitoring
NT – Tachometer voltage normalization
NS – Speed setpoint normalization
SH – Lift start pulse
NZ – Additional setpoint normalization
HR – Clockwise acceleration ramp
AR – Clockwise deceleration ramp
HL – Anticlockwise acceleration ramp
AL – Anticlockwise deceleration ramp
VR – n controller gain
ND – Speed monitoring normalization
ST – Setpoint in controlled range
BR – Standstill monitoring
S1 – Switching logic rotor contactor stage 1
S2 – Switching logic rotor contactor stage 2
S3 – Switching logic rotor contactor stage 3
S4 – Switching logic rotor contactor stage 4
*) If the ramp-up and ramp-down functions for clockwise and anti-clockwise rotation are to be set
separately, the function data set must be switched over.
18-2
range)
pre-warning")
U621.001 = 162
U621.002 = 162
U622.001 = 540
U622.002 = 540
U623.001 = 165
U623.002 = 165
For SIMOTRAS HD this is Term. 89/90
For SIMOTRAS HD this is Term. 91/92
For SIMOTRAS HD this is Term. 93/94
Terminals 90, 92 and 94 must be linked
For SIMOTRAS HD this is Term. 109/110 [G112.6]
U619.001 = 148
U619.002 = 148
Corresponding parameter on SIMOTRAS HD
(6SG70 series)
P319 (factory setting = 0.05 s)
This function must be implemented using free
modules if required (similar to ramp-down
monitoring on Sheet K15 in Section 8)
P741 (factory setting = 60.00 V)
P320 (factory setting = 100.00 %)
U651 (factory setting = 0.00 %)
No setting necessary as the "zero delay angle"
function is implemented in a different way.
P303 (factory setting = 10.00 s) *)
P304 (factory setting = 10.00 s) *)
P303 (factory setting = 10.00 s) *)
P304 (factory setting = 10.00 s) *)
P225 (factory setting = 3.00)
P388 (factory setting = 5.00 %)
U628 (factory setting = 55.0 %)
P370 (factory setting = 5.00 %)
U630 (factory setting = - 1.0 %)
U634 (factory setting = 50.0 %)
U636 (factory setting = 75.0 %)
U638 (factory setting = 90.0 %)
SIMOTRAS HD
01.04
[G119.3]
[G119.3]
[G119.3]
[G119.3]
[G119.3]
[G119.3]
[G119.4]
[G119.4]
[G119.4]
[G119.4]
[G112.3]
[G112.3]
[G136.2]
[G113.2]
[G135.2]
[G150.2]
[G136.2]
[G136.3]
[G136.2]
[G136.3]
[G151.2]
[G187.5]
[G160.6]
[G188.4]
[G119.2]
[G119.6]
[G119.6]
[G119.6]
SIEMENS AG
6SG7000-0BA76
Operating Instructions

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents