Siemens SIMOTRAS 6SG7050 Operating Instructions Manual page 451

6sg70 series
Table of Contents

Advertisement

01.04
PNU
Description
Characteristic block 2 (output = K9230)
Characteristic block 6 (output = K9412) [SW1.8 and later]
Characteristic block 7 (output = K9413) [SW1.8 and later]
U284
Source for input quantity
(2284)
0 = Connector K0000
*
1 = Connector K0001
S00
etc.
(B160)
up to SW 1.7:
Selected connector = input quantity for FB107
SW 1.8 and later:
i001
input quantity
i002
input quantity
i003
input quantity
U285
x values
(2285)
i001
1st characteristic point
S00
i002
2nd characteristic point
...
(B160)
i010
10th characteristic point for FB107
SW 1.8 and later:
i011
1st characteristic point
i012
2nd characteristic point
...
i020
10th characteristic point for FB282
i021
1st characteristic point
i022
2nd characteristic point
...
i030
10th characteristic point for FB283
U286
y values
(2286)
i001
1st characteristic point
S00
i002
2nd characteristic point
...
(B160)
i010
10th characteristic point for FB107
SW 1.8 and later:
i011
1st characteristic point
i012
2nd characteristic point
...
i020
10th characteristic point for FB282
i021
1st characteristic point
i022
2nd characteristic point
...
i030
10th characteristic point for FB283
Characteristic block 3 (Output = K9231)
Characteristic block 8 (Output = K9414) [SW1.8 and later]
Characteristic block 9 (Output = K9415) [SW1.8 and later]
U287
Source for input quantity
(2287)
0 = Connector K0000
*
1 = Connector K0001
S00
etc.
(B160)
up to SW 1.7:
Selected connector = input quantity for FB108
SW 1.8 and later:
i001
Input quantity
i002
Input quantity
i003
Input quantity
SIEMENS AG
6SG7000-0BA76
SIMOTRAS HD
Operating Instructions
for FB107
for FB282
for FB283.
for FB107
for FB107
for FB282
for FB282
for FB283
for FB283
for FB107
for FB107
for FB282
for FB282
for FB283
for FB283
for FB108
for FB284
for FB285
Value range
No. indices
[Unit]
All connector
Ind: 3
numbers
FS=0
1
Type: L2
-200.00 to 199.99
Ind: 30
[%]
FS=0.00
0.01
Type: I2
-200.00 to 199.99
Ind: 30
[%]
FS=0.00
0.01
Type: I2
All connector
Ind: 3
numbers
FS=0
1
Type: L2
Parameter list
See
Change
FB 107
FB 282
FB 283
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Online
FB 108
FB 284
FB 285
P052 = 3
P051 = 40
Offline
11-103

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents