Siemens SIMOTRAS 6SG7050 Operating Instructions Manual page 358

6sg70 series
Table of Contents

Advertisement

Parameter list
PNU
Description
11.3
Access authorization levels
P051
Key parameters
*
0
No access authorization
6
Do not set (for use by DriveMonitor)
7
Do not set (for use by DriveMonitor)
9
Do not set (for use by DriveMonitor)
21
Restore factory settings
All parameters are reset to their defaults (factory settings).
Parameter P051 is then automatically reset to factory setting
"40".
22
Do not set
25
Do not set
26
Do not set
27
Do not set
28
Do not set
29
Do not set
40
Access authorization to parameter values for authorized service
personnel
P052
Selection of display parameters
*
0
0
Display only parameters that are not set to original factory
settings
1
Display only parameters for simple applications
3
Display all parameters used
P053
Control word for the permanent memory
*
Disabling or enabling write accesses to the permanent memory
i001:
Disabling or enabling write accesses to the parameter memory
0
Only save parameter P053 in the permanent memory;
parameter changes are active immediately but the changed
values are only stored temporarily and are lost when the
electronics supply voltage is switched off
1
Save all parameter values in the permanent memory
i002:
Disabling or enabling write accesses to the memory of the
nonvolatile process data
0
Do not save nonvolatile process data in the permanent
memory
1
Save all nonvolatile process data in the permanent memory
If the nonvolatile process data are not stored (P053.002=0),
data are lost when the electronics supply of the SIMOTRAS HD
is switched off, i.e. they have the value 0 after the electronics
supply is switched on again:
K0240: Setpoint of the motor potentiometer
K0309: Motor heating
K0310: Thyristor heating
K9195: Output of the 1st tracking/storage element
K9196: Output of the 2nd tracking/storage element
P054
OP1S – Background lighting
0
ON continuously
1
ON when panel is in use
11-10
Value range
[Unit]
see Column 2
0, 1, 3
0 to 1
[SW 1.7 and later]
1
0, 1
No. indices
Ind: None
FS=40
Type: O2
Ind: None
FS=3
Type: O2
Ind: 2
FS=1
Type: O2
Ind: None
FS=0
Type: O2
SIEMENS AG
6SG7000-0BA76
SIMOTRAS HD
Operating Instructions
01.04
See
Change
P052 = 3
P051 ≥ 0
Online
P052 = 3
P051 ≥ 0
Online
P052 = 3
P051 = 0
Online
P052 = 3
P051 ≥ 0
Online

Hide quick links: