Siemens SIMOTRAS 6SG7050 Operating Instructions Manual page 365

6sg70 series
Table of Contents

Advertisement

01.04
PNU
Description
P095
Pick-up time for a contactor in the motor circuit
If the output (terminals U2, V2, W2) is switched through to the motor via a
contactor, and if this contactor is controlled by the relay output terminals
109 and 110, then the gating pulses may not be enabled until the contactor
has safely picked up. For this purpose, it may be necessary to
parameterize an additional delay time for the pick-up operation. The timer
set in P095 commences during a pick-up operation when the converter
reaches operating state o4. If the timer has still not run down by the time
the converter exits state o4, then the converter dwells in state o3.2 until the
timer has finished.
During the time period set in P095, the "Main contactor checkback" signal
must also switch to "1" if this function is activated (see P691). Otherwise
the converter dwells in state o3.3 until the timer has finished and fault
message F004 is then output with fault value 6.
P096
Run-on time for the converter fan
After the drive has stopped (an operating state ≥ 7.0 is reached), the fan
continues to run until the power section has cooled down.
This parameter can be used to set the minimum run-on time.
11.7
Definition of motor
P100
Rated motor current (acc. to motor rating plate)
*
0.0
Parameter not yet set
FDS
P113
Continuous current factor torque control / current control
*
This parameter defines the current to be permitted as a continuous current
FDS
2
by the I
t motor monitoring function without activation of alarm message
A037 or fault message F037.
This current is the product of calculation P113 * P100.
P114
Thermal time constant of motor
(see Section 9.10)
FDS
2
0.0
I
t monitoring deactivated
SIEMENS AG
6SG7000-0BA76
SIMOTRAS HD
Operating Instructions
Value range
No. indices
[Unit]
0.00 to 1.00
Ind: None
[s]
FS=0.00
0.01s
Type: O2
0.0 to 60.0
Ind: None
[min]
FS=4.0
0.1min
Type: O2
0.0 to 6553.0
Ind: 4
[A]
FS=0.0
0.1A
Type: O2
0.50 to 2.00
Ind: 4
0.01
FS=1.00
Type: O2
0.0 to 80.0
Ind: 4
[min]
FS=10.0
0.1min
Type: O2
Parameter list
See
Change
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Online
11-17