Siemens SIMOTRAS 6SG7050 Operating Instructions Manual page 391

6sg70 series
Table of Contents

Advertisement

01.04
PNU
Description
P555
Source for the Influencing quantity of the droop adaptation
*
Selection of which connector is connected at the influencing quantity for
FDS
adaptation of the n controllers droop
(G151)
0 = Connector K0000
1 = Connector K0001
etc.
P556
Adaptation of n controller P gain: Threshold 1
FDS
(G151)
P557
Adaptation n controller integration time: Threshold 1[SW 1.7 and later]
FDS
(G151)
P558
Adaptation n controller droop: Threshold 1
FDS
(G151)
P559
Adaptation of n controller P gain: Threshold 2
FDS
(G151)
P560
Adaptation n controller integration time: Threshold 2[SW 1.7 and later]
FDS
(G151)
P561
Adaptation n controller droop: Threshold 2
FDS
(G151)
Speed controller - speed droop limitation
P562
Positive speed droop limitation
FDS
(G151)
P563
Negative speed droop limitation
FDS
(G151)
11.31 Input quantities for signals
(see also Section 8, Sheets G187 and G188)
P590
Source for setpoint of "nset = nact signal 1"
*
Setpoint/actual value deviation signal:
Selection of connector to be injected as input quantity "n set " for the
(G187)
setpoint/actual value deviation signal.
0 = connector K0000
1 = connector K0001
etc.
P591
Source for actual value of "n-set = n-act signal 1"
*
Setpoint/actual value deviation signal:
Selection of connector to be injected as input quantity "n act " for the
(G187)
setpoint/actual value deviation signal.
0 = connector K0000
1 = connector K0001
etc.
P592
Source for actual value of "n < n comp. signal"
*
n < n comp. signal:
Selection of connector to be injected as input quantity (n) for the
(G187)
n < n comp. signal.
0 = connector K0000
1 = connector K0001
etc.
P593
Source for actual value of "n < n min signal"
*
n < n min signal:
Selection of connector to be injected as input quantity (n) for the n < n min
(G188)
signal.
0 = connector K0000
1 = connector K0001
etc.
SIEMENS AG
6SG7000-0BA76
SIMOTRAS HD
Operating Instructions
Value range
[Unit]
All connector
[SW 1.7 and later]
numbers
1
0.00 to 100.00
[%]
0.01%
0.00 to 100.00
[%]
0.01%
[SW 1.7 and later]
0.00 to 100.00
[%]
0.01%
0.00 to 100.00
[%]
0.01%
0.00 to 100.00
[%]
0.01%
[SW 1.7 and later]
0.00 to 100.00
[%]
0.01%
0.00 to 199.99
[%]
0.01%
-199.99 to 0.00
[%]
0.01%
All connector
numbers
1
All connector
numbers
1
All connector
numbers
1
All connector
numbers
1
Parameter list
No. indices
See
Change
Ind: 4
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: 4
P052 = 3
FS=0.00
P051 = 40
Type: O2
Online
Ind: 4
P052 = 3
FS=0.00
P051 = 40
Type: O2
Online
Ind: 4
P052 = 3
FS=0.00
P051 = 40
Type: O2
Online
Ind: 4
P052 = 3
FS=0.00
P051 = 40
Type: O2
Online
Ind: 4
P052 = 3
FS=0.00
P051 = 40
Type: O2
Online
Ind: 4
P052 = 3
FS=0.00
P051 = 40
Type: O2
Online
Ind: 4
P052 = 3
FS=100.00
P051 = 40
Type: O2
Online
Ind: 4
P052 = 3
FS=-100.00
P051 = 40
Type: I2
Online
Ind: None
P052 = 3
FS=174
P051 = 40
Type: L2
Offline
Ind: None
P052 = 3
FS=167
P051 = 40
Type: L2
Offline
Ind: None
P052 = 3
FS=167
P051 = 40
Type: L2
Offline
Ind: None
P052 = 3
FS=167
P051 = 40
Type: L2
Offline
11-43