Installation
Supplementary boards may be inserted in any slot subject to the following restrictions:
NOTICE
♦ Slot 3 must not be used until slot 2 is already occupied.
♦ A technology board must always be installed in board location 2 of the electronics box.
♦ If a technology board is used in conjunction with one communication board, then the
communication board must be fitted in slot G (miniature-format boards, for example CBP2
and CBC) or slot 3 (large-format board SCB1).
♦ It is not possible to operate boards EB1, EB2, SLB and SBP in conjunction with a technology
board.
♦ The data of large-format boards are always output under slot E or slot G, i.e. the software
version of a technology board, for example, is displayed in r060.003.
♦ In addition to the LBA, miniature-format boards (for example CBP2 and CBC) also require an
ADB (adapter board, support board). Due to their very compact physical dimensions, these
boards must be inserted in an ADB before they can be installed in the electronics box.
♦ A total of two supplementary boards of the same type can be used (e.g. 2 EB1s), but only 1
SBP and 1 SLB may be installed.
For information about starting up supplementary boards, please refer to Section 7.10 "Starting up
optional supplementary boards".