Siemens SIMOTRAS 6SG7050 Operating Instructions Manual page 500

6sg70 series
Table of Contents

Advertisement

Parameter list
PNU
Description
n810
Diagnostic information for the paralleling interface [SW 2.1 and later]
(2810)
(G195)
Paralleling master: (i.e. when U800 = 1)
Segment
0 ........
1 ........
2 ........ ON: Slave with address 2 responding
3 ........ ON: Slave with address 3 responding
4 ........ ON: Slave with address 4 responding
5 ........ ON: Slave with address 5 responding
6 ........ ON: Slave with address 6 responding
7 ........
8 ........ OFF
9 ........ OFF
10 ........
11 ........
12 ........
13 ........
14 ........
15 ........ ON: Master function active
Paralleling slave: (i.e. when U800 = 2)
Segment
0 ........
1 ........
2 ........ ON: Data for slave with address 2 are ok
3 ........ ON: Data for slave with address 3 are ok
4 ........ ON: Data for slave with address 4 are ok
5 ........ ON: Data for slave with address 5 are ok
6 ........ ON: Data for slave with address 6 are ok
7 ........
8 ........ ON: Slave function active
9 ........ ON: Firing pulses of master are used
10 ........
11 ........
12 ........
13 ........
14 ........
15 ........ OFF
11-152
15
14
13
12
11
10
9
6
4
7
5
3
2
1
Value range
[Unit]
8
0
No. indices
Ind: None
Type: V2
SIEMENS AG
6SG7000-0BA76
SIMOTRAS HD
Operating Instructions
01.04
See
Change
P052 = 3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents