01.04
PNU
Description
U640
Wait period when switching rotor contactors
(2640)
i 001:
Pick-up time of rotor contactors
i 002:
Drop-out time of rotor contactors
i 003:
Pick-up time of rotor contactors
(see header for parameter U641 ff.)
Off-load switching is recommended to increase the service life of the rotor
contactors.
A disadvantage of off-load switching of rotor contactors: there is a torque-
free interval, and this may lead to a deviation in the speed.
Whenever a rotor contactor is switched in, the firing pulses are disabled for
the time set at index 001 (zero current interval).
Whenever a rotor contactor is switched out, the firing pulses are disabled
for the time set at index 002 (zero current interval).
Preventing current peaks during rotor stage stepping:
To prevent excessive stator current values occurring when switching in the next rotor contactor, it is desirable, at the same time as the
contactor is switched in (delayed by the time set at U640 index 003), to reduce the I component of the speed controller by roughly the
same proportion by which the rotor resistance is also reduced.
U641
Factor for I component n controller with rotor stage 1
(2641)
R (stage 1) / R (counter-torque stage)
FDS
U642
Factor for I component n controller with rotor stage 2
(2642)
R (stage 2) / R (stage 1)
FDS
U643
Factor for I component n controller with rotor stage 3
(2643)
R (stage 3) / R (stage 2)
FDS
U644
Factor for I component n controller with rotor stage 4
(2644)
R (stage 4) / R (stage 4)
FDS
U645
Factor for P component n controller with counter-torque operation
(2645)
effective P gain for speed controller with counter-torque operation = P225 *
FDS
U645
(G151)
U646
Factor for P component n controller with rotor stage 1
(2646)
effective P gain for speed controller with rotor stage 1 = P225 * U646
FDS
(G151)
U647
Factor for P component n controller with rotor stage 2
(2647)
effective P gain for speed controller with rotor stage 2 = P225 * U647
FDS
(G151)
U648
Factor for P component n controller with rotor stage 3
(2648)
effective P gain for speed controller with rotor stage 3 = P225 * U648
FDS
(G151)
U649
Factor for P component n controller with rotor stage 4
(2649)
effective P gain for speed controller with rotor stage 4 = P225 * U649
FDS
(G151)
11.73 Start pulse, speed controller
(see also Section 8, Sheet G150)
U651
Start pulse (integrator setting value for the speed controller)
(2651)
FDS
(G150)
U652
Multiplier for start pulse when lowering
(2652)
when start pulse as in U651 is also used for a positive setpoint (lowering)
FDS
(G150)
SIEMENS AG
6SG7000-0BA76
SIMOTRAS HD
Operating Instructions
Value range
No. indices
[Unit]
0 to 2000
Ind: 3
[ms]
FS=
1ms
i001: 0
i002: 0
i003: 50
Type: O2
0.0 to 100.0
Ind: 4
[%]
FS=50.0
0.1%
Type: O2
0.0 to 100.0
Ind: 4
[%]
FS=50.0
0.1%
Type: O2
0.0 to 100.0
Ind: 4
[%]
FS=50.0
0.1%
Type: O2
0.0 to 100.0
Ind: 4
[%]
FS=50.0
0.1%
Type: O2
1 to 1000
Ind: 4
[%]
FS=100
1%
Type: O2
1 to 1000
Ind: 4
[%]
FS=100
1%
Type: O2
1 to 1000
Ind: 4
[%]
FS=100
1%
Type: O2
1 to 1000
Ind: 4
[%]
FS=100
1%
Type: O2
1 to 1000
Ind: 4
[%]
FS=100
1%
Type: O2
-100.00 to 100.00
Ind: 4
[%]
FS=0.00
0.01%
Type: I2
0.00 to 100.00
Ind: 4
[%]
FS=50.00
0.01%
Type: O2
Parameter list
See
Change
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Online
11-131

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents