Siemens SIMOTRAS 6SG7050 Operating Instructions Manual page 428

6sg70 series
Table of Contents

Advertisement

Parameter list
PNU
Description
n042
Warning memory
Warning memory for flagging warnings that have occurred since the
(2042)
electronics supply voltage was last switched on.
The contents of the warning memory are lost when the electronics supply
voltage is switched off and can be deleted with U043.
The warnings are displayed in bit code as for r953 to r960
i001:
Display of warnings 1 to 16
i002:
Display of warnings 17 to 32
i003:
Display of warnings 33 to 48
i004:
Display of warnings 49 to 64
i005:
Display of warnings 65 to 80
i006:
Display of warnings 81 to 96
i007:
Display of warnings 97 to 112
i008:
Display of warnings 113 to 128
See Section 10.2 for the meaning of the individual warnings
U043
Deleting the warning memory
*
Settings:
(2043)
0
Deletes the entire warning memory n042 by resetting it to 0.
Subsequently the parameter is automatically set back to value
1.
1
Not active
U044
Connector display, decimal
(2044)
Selects those connectors whose value is to be displayed as a decimal with
*
n045
(G121)
i001:
Selects the connector to be displayed with n045.01
i002:
Selects the connector to be displayed with n045.02
i003:
Selects the connector to be displayed with n045.03
i004:
Selects the connector to be displayed with n045.04
i005:
Selects the connector to be displayed with n045.05
n045
Connector display, decimal
(2045)
Decimal display with sign of the values of the connectors selected with
U044. In the case of double-word connectors the H word is displayed.
(G121)
i001:
Display of the connector selected with U044.01
i002:
Display of the connector selected with U044.02
i003:
Display of the connector selected with U044.03
i004:
Display of the connector selected with U044.04
i005:
Display of the connector selected with U044.05
U046
Connector display, hexadecimal
(2046)
Selection of connectors whose value is to be displayed as a hexadecimal
*
value with n047l
(G121)
i001:
Selection of the connector to be displayed with n047.01
i002:
Selection of the connector to be displayed with n047.02
i003:
Selection of the connector to be displayed with n047.03
i004:
Selection of the connector to be displayed with n047.04
i005:
Selection of the connector to be displayed with n047.05
n047
Connector display, hexadecimal
(2047)
Hexadecimal display of values of connectors selected with U046. In the
case of double-word connectors the H word is displayed.
(G121)
i001:
Display of the connector selected with U046.01
i002:
Display of the connector selected with U046.02
i003:
Display of the connector selected with U046.03
i004:
Display of the connector selected with U046.04
i005:
Display of the connector selected with U046.05
11-80
Value range
[Unit]
[SW 2.0 and later]
0 to 1
[SW 2.0 and later]
1
[SW 2.0 and later]
All connector
numbers
1
-32768 to 32767
[SW 2.0 and later]
1
All connector
[SW 2.0 and later]
numbers
1
[SW 2.0 and later]
0000h to FFFFh
1
No. indices
Ind: 8
Type: V2
Ind: none
FS=1
Type: O2
Ind: 5
FS=0
Type: L2
Ind:5
Type: I2
Ind: 5
FS=0
Type: L2
Ind:5
Type: L2
SIEMENS AG
6SG7000-0BA76
SIMOTRAS HD
Operating Instructions
01.04
See
Change
P052 = 2
P052 = 3
P052 = 3
P051 =40
Online
P052 = 3
P052 = 3
P051 =40
Online
P052 = 3

Hide quick links:

Advertisement

Table of Contents
loading