Siemens SIMOTRAS 6SG7050 Operating Instructions Manual page 356

6sg70 series
Table of Contents

Advertisement

Parameter list
PNU
Description
r023
Display of speed controller setpoint/actual value deviation
(G152)
r024
Display of actual speed value from pulse encoder
(G145)
r025
Display of actual speed controller value
(G151)
r026
Display of speed controller setpoint
(G152)
r027
Display of ramp-function generator output
(G136)
r028
Display of ramp-function generator input
(G136)
r029
Display of main setpoint before limitation
(G135)
r040
Display of limitations:
Representation on operator panel (PMU):
Segment ON:
Segment OFF:
Segment or bit
0 ........ Reserved
1 ........ Reserved
2 ........ α W limit reached
3 ........ Negative current limit reached (K0132)
4 ........ Negative maximum speed reached (P513)
5 ........ Negative torque limit reached (B0203)
6 ........ Neg. limitation at ramp generator output reached
7 ........ Neg. limitation at ramp generator input reached
8 ........ Reserved
9 ........ Reserved
10 ........ α G limit reached
11 ........ Positive current limit reached (K0131)
12 ........ Positive maximum speed reached (P512)
13 ........ Positive torque limit reached (B0202)
14 ........ Pos. limitation at ramp generator output reached
15 ........ Pos. limitation at ramp generator input reached
Note:
This parameter has the same bit assignments as connector K0810.
Connector and binector displays
r041
High-resolution connector display:
i001:
Display of connector selected in P042.01
(G121)
i002:
Display of connector selected in P042.02
The display value is filtered with a time constant of 300ms (see Section 8,
Sheet G121)
P042
High-resolution connector display:
*
i001:
Selection of connector to be displayed in r041.01
i002:
Selection of connector to be displayed in r041.02
(G121)
The display value is filtered with a time constant of 300ms (see Section 8,
Sheet G121)
11-8
15
14
13
12
11
10
9
6
4
7
5
3
2
1
Corresponding limitation is reached
Corresponding limitation is not reached
Speed limiting controller responds (B0201)
. (K0182)
. (K0197)
Speed limiting controller responds (B0201)
. (K0181)
. (K0196)
Value range
[Unit]
-200.00 to 199.99
[%]
0.01%
-200.00 to 199.99
[%]
0.01%
-200.00 to 199.99
[%]
0.01%
-200.00 to 199.99
[%]
0.01%
-200.00 to 199.99
[%]
0.01%
-200.00 to 199.99
[%]
0.01%
-200.00 to 199.99
[%]
0.01%
8
0
-200.00 to 199.99
[%]
0.01%
All connector
numbers
1
No. indices
Ind: None
Type: I2
Ind: None
Type: I2
Ind: None
Type: I2
Ind: None
Type: I2
Ind: None
Type: I2
Ind: None
Type: I2
Ind: None
Type: I2
Ind: None
Type: V2
Ind: 2
Type: I2
Ind: 2
FS=0
Type: L2
SIEMENS AG
6SG7000-0BA76
SIMOTRAS HD
Operating Instructions
01.04
See
Change
P052 = 3
P052 = 3
P052 = 3
P052 = 3
P052 = 3
P052 = 3
P052 = 3
P052 = 3
P052 = 3
P052 = 3
P051 = 40
Online

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents