Siemens SIMOTRAS 6SG7050 Operating Instructions Manual page 408

6sg70 series
Table of Contents

Advertisement

Parameter list
PNU
Description
P758
Normalization of analog output 2
P
(G115)
=
y V
[ ]
x
100
x = normalization input (corresponds to filtering output)
y = normalization output (corresponds to output voltage at analog output
with an offset of 0)
P759
Offset for analog output 2
(G115)
Analog output, terminal 18 / 19
P760
Source for output value at analog output 3
*
0 = connector K0000
1 = connector K0001
(G116)
etc.
P761
Mode of signal injection at analog output 3
*
0 = Injection of signal with sign
1 = Injection of absolute value of signal
(G116)
2 = Injection of signal with sign, inverted
3 = Injection of absolute value of signal, inverted
P762
Filtering time for analog output 3
(G116)
P763
Normalization of analog output 3
P
(G116)
=
y V
[ ]
x
100
x = normalization input (corresponds to filtering output)
y = normalization output (corresponds to output voltage at analog output
with an offset of 0)
P764
Offset for analog output 3
(G116)
Analog output, terminal 20 / 21
P765
Source for output value at analog output 4
*
0 = connector K0000
1 = connector K0001
(G116)
etc.
P766
Mode of signal injection at analog output 4
*
0 = Injection of signal with sign
1 = Injection of absolute value of signal
(G116)
2 = Injection of signal with sign, inverted
3 = Injection of absolute value of signal, inverted
P767
Filtering time for analog output 4
(G116)
P768
Normalization of analog output 4
P
(G116)
=
y V
[ ]
x
100
x = normalization input (corresponds to filtering output)
y = normalization output (corresponds to output voltage at analog output
with an offset of 0)
P769
Offset for analog output 4
(G116)
11-60
758
%
763
%
768
%
Value range
No. indices
[Unit]
-200.00 to 199.99
Ind: None
[V]
FS=10.00
0.01V
Type: I2
-10.00 to 10.00
Ind: None
[V]
FS=0.00
0.01V
Type: I2
All connector
Ind: None
numbers
FS=0
1
Type: L2
0 to 3
Ind: None
1
FS=0
Type: O2
0 to 10000
Ind: None
[ms]
FS=0
1ms
Type: O2
-200.00 to 199.99
Ind: None
[V]
FS=10.00
0.01V
Type: I2
-10.00 to 10.00
Ind: None
[V]
FS=0.00
0.01V
Type: I2
All connector
Ind: None
numbers
FS=0
1
Type: L2
0 to 3
Ind: None
1
FS=0
Type: O2
0 to 10000
Ind: None
[ms]
FS=0
1ms
Type: O2
-200.00 to 199.99
Ind: None
[V]
FS=10.00
0.01V
Type: I2
-10.00 to 10.00
Ind: None
[V]
FS=0.00
0.01V
Type: I2
SIEMENS AG
SIMOTRAS HD
Operating Instructions
01.04
See
Change
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Online
6SG7000-0BA76

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents