Siemens SIMOTRAS 6SG7050 Operating Instructions Manual page 516

6sg70 series
Table of Contents

Advertisement

Connectors and binectors
Connector
Description
Fixed setpoints
K0401
Fixed value 1 (P401)
Fixed value 2 (P402)
K0402
K0403
Fixed value 3 (P403)
Fixed value 4 (P404)
K0404
K0405
Fixed value 5 (P405)
K0406
Fixed value 6 (P406)
Fixed value 7 (P407)
K0407
K0408
Fixed value 8 (P408)
Fixed value 9 (P409)
K0409
K0410
Fixed value 10 (P410)
K0411
Fixed value 11 (P411)
Fixed value 12 (P412)
K0412
K0413
Fixed value 13 (P413)
Fixed value 14 (P414)
K0414
K0415
Fixed value 15 (P415)
K0416
Fixed value 16 (P416)
Start pulse for speed controller
Fixed setting value 1 for n controller I component
K0451
K0452
Fixed setting value 1 for n controller I component, weighted
Fixed setting value 2 for n controller I component
K0453
K0454
Setting value 1 for n controller I component
Control inputs, control outputs
Binary inputs, terminals 72 to 79
K0500
Bit0 = Status of terminal 72
Bit1 = Status of terminal 73
Bit2 = Status of terminal 74
Bit3 = Status of terminal 75
Bit4 = Status of terminal 76
Bit5 = Status of terminal 77
Bit6 = Status of terminal 78
Bit7 = Status of terminal 79
K0501
Binary outputs terminals 81/82 to 93/94
Bit0 = Status of terminal 81/82
Bit1 = Status of terminal 83/84
Bit2 = Status of terminal 85/86
Bit3 = Status of terminal 87/88
Bit4 = Status of terminal 89/90
Bit5 = Status of terminal 91/92
Bit6 = Status of terminal 93/94
4 stage master switch
K0510
Setpoint of 4-stage master switch
General connectors
Operating status (code number) with one decimal place
K0800
K0801
Latest fault and alarm message
Low byte: Latest alarm message
If several alarms are active simultaneously, the alarm with the
lowest number if displayed here.
Value "0" means that no alarm is active.
High byte: Latest fault message
Value "0" means that no fault is active.
12-6
Normalization
∧ 100%
=
16384
∧ 100%
=
16384
∧ 100%
=
16384
∧ 100%
=
16384
∧ 100%
=
16384
∧ 100%
=
16384
∧ 100%
=
16384
∧ 100%
=
16384
∧ 100%
=
16384
∧ 100%
=
16384
∧ 100%
=
16384
∧ 100%
=
16384
∧ 100%
=
16384
∧ 100%
=
16384
∧ 100%
=
16384
∧ 100%
=
16384
∧ 100% of P100
=
16384
∧ 100% of P100
=
16384
∧ 100% of P100
=
16384
∧ 100% of P100
=
16384
Bit = 0: Input is LOW
(not activated)
Bit = 1: Input is HIGH
(activated)
Bit = 0: Output relay has not
picked up
Bit = 1: Output relay has
picked up
∧ 100%
=
16384
SIEMENS AG
SIMOTRAS HD
Operating Instructions
01.04
Function
diag., Sheet
G120
G120
G120
G120
G120
G120
G120
G120
G120
G120
G120
G120
G120
G120
G120
G120
G150
G150
G150
G150
G117
G119
G125
G189
6SG7000-0BA76

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents