Connectors and binectors
Connector
Description
Firing pulse cycle time (time difference between current and previous firing
K0988
instant) in T1 increments of 1.334 µs each
K0989
Information about torque direction and firing angle
Nibble 0 ..
Torque direction
0 = M0 (--)
1 = MI
2 = MII
9 = Reserved
Nibble 1 ..
Code number for firing angle
1 = Requested firing angle has been implemented
2 = Reserved
3 = Firing angle at 180°
4 = Firing angle at 180°
5 = Requested firing angle cannot be implemented because of
6 = Reserved
7 = Reserved
8 = Reserved
Nibble 2 ..
Code number for requested torque direction
0: Not RUN ( ≥ o1.0)
1: Torque direction acc. to current setpoint (==> M0, MI, MII)
2: Reserved
3: Reserved
4: Additional wait time in auto-reversing stage (==> M0)
5: Current has reached 0 (==> M0), phase reversal permitted
6: Current not yet 0 (==> M0), phase reversal not permitted
7: Reserved
8: Reserved
9: Reserved
A: Wait for rotor contactor to switch (==> M0)
B: Reserved
C: Reserved
D: Reserved
E: Reserved
F: Reserved
Nibble 3 ..
Code number for zero current signal
0: The "I=0" signal is not evaluated because no change in
1: I <> 0
2: I = 0 for less than 0.1 msec
3: I = 0 for more than 0.1 msec
4: I = 0 for more than 0.6 msec
5: Ia-act (K116) is < 1 % for more than 6 current peaks
Current total processor capacity utilization (C167)
K0990
K0991
Projected total processor capacity utilization (C167) for maximum line
frequency (65Hz)
Current total processor capacity (C167) utilized by background routines
K0992
K0994
Total processor capacity (C167) currently utilized by routines synchronized
with firing pulses
Serial interface 1 (USS1 on G-SST1)
K2001
USS1 receive data, word 1
K2002
USS1 receive data, word 2
K2003
USS1 receive data, word 3
K2004
USS1 receive data, word 4
USS1 receive data, word 5
K2005
K2006
USS1 receive data, word 6
USS1 receive data, word 7
K2007
K2008
USS1 receive data, word 8
USS1 receive data, word 9
K2009
K2010
USS1 receive data, word 10
USS1 receive data, word 11
K2011
12-8
strong pulse compression
yet
torque direction is required
Normalization
[SW 1.9 and later]
∧ 1
=
1
∧ 1
=
1
∧ 1
=
1
∧ 1
=
1
∧ 1
=
1
∧ 1
=
1
∧ 1
=
1
∧ 1
=
1
∧ 1
=
1
∧ 1
=
1
∧ 1
=
1
Function
diag., Sheet
G170
G170
G170
G170
G170
G170
G170
G170
G170
G170
G170
SIEMENS AG
6SG7000-0BA76
SIMOTRAS HD