PNU
Description
U509
Source for variable negative limit
(2509)
After multiplication with U510, the contents of the selected connector act as
*
a negative limit for the technology controller output.
S00
0 = connector K0000
(B170)
1 = connector K0001
etc.
Note:
If the selected connector contains a positive value, a positive minimum
value is applied to the output of this limiter stage.
Note:
Connector K9252 contains the positive limiting value with inverted sign
generated by U507 and U508. By setting U509=9252 and U510=100.0,
therefore, it is possible to set the negative and positive limits symmetrically.
U510
Negative limit for technology controller output
(2510)
See also U509
S00
FDS
(B170)
U511
Source for variable weighting factor for output
(2511)
After multiplication with U512, the contents of the selected connector act as
*
a weighting factor for the technology controller output.
S00
(B170)
0 = connector K0000
1 = connector K0001
etc.
U512
Weighting factor for output
(2512)
See also U511
S00
FDS
(B170)
11.67 Velocity/speed calculator
Speed/velocity calculator
D
=
Function:
v
_
act
v_act
Actual velocity
D
Diameter
n_rated
Rated speed
i
Gear ratio
n_act
Actual speed
U515
Source for actual speed
(2515)
0 = connector K0000
*
1 = connector K0001
S00
etc.
(B190)
Velocity/speed calculator
=
Function:
n
_
set
D
n_set
Setpoint speed
D
Diameter
n_rated
Rated speed
i
Gear ratio
v_set
Setpoint velocity
U516
Source for set velocity
(2516)
A value of 16384 in the selected connector is equivalent to the set velocity
*
set in U522
S00
0 = Connector K0000
(B190)
1 = Connector K0001
etc.
11-122
π
n
_
rated
n
_
act
i
100
%
(n021, U521, K9256)
(U517, U518)
(U520)
(U519)
(U515)
v
_
set
i
100
%
π
n
_
rated
(n023, K9257)
(U517, U518, U523)
(U520)
(U519)
(U516, U522)
Value range
[Unit]
All connector
FB 114
numbers
1
0.0 to 199.9
FB 114
[%]
0.1
FB 114
All connector
numbers
1
FB 114
-100.0 to 100.0
[%]
0.01
FB 115
All connector
numbers
1
FB 115
All connector
numbers
1
SIEMENS AG
SIMOTRAS HD
01.04
No. indices
See
Change
Ind: None
P052 = 3
FS=9252
P051 = 40
Type: L2
Offline
Ind: 4
P052 = 3
FS=100.0
P051 = 40
Type: O2
Online
Ind: None
P052 = 3
FS=1
P051 = 40
Type: L2
Offline
Ind: 4
P052 = 3
FS=100.0
P051 = 40
Type: I2
Online
Ind: None
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: None
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
6SG7000-0BA76
Operating Instructions

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents