Parameter list
PNU
Description
U676
Source for positional deviation offset
(2676)
*
Selection of the connector whose value is to be used as the offset of the
S00
positional deviation
(B152)
Settings:
0 = Connector K0000
1 = Connector K0001
etc.
U677
Fixed values for position acquisition
(2677)
*
i001:
LOW word of double-word connector KK9471
S00
i002:
HIGH word of double-word connector KK9471
(B152)
i003:
LOW word of double-word connector KK9472
i004:
HIGH word of double-word connector KK9472
i005:
LOW word of double-word connector KK9473
i006:
HIGH word of double-word connector KK9473
i007:
LOW word of double-word connector KK9474
i008:
HIGH word of double-word connector KK9474
U678
Memory for actual position values: Initial value at POWER ON FB 54
(2678)
*
0
Initial value = 0
S00
1
Initial value is set such that on POWER ON KK9481 or KK9482
(B152)
assumes whatever its setting value was before the electronics
supply was disconnected.
11.76 Root extractor
U680
Source for the input of the root extractor
(2680)
*
Selection of the connector whose value is to be used for the root extractor
S00
input.
(B153)
Settings:
0 = Connector K0000
1 = Connector K0001
etc.
U681
Operating point for limit monitoring indicator of the root extractor
(2681)
S00
(B153)
applied to connector KK9483
U682
Hysteresis for limit monitoring indicator of the root extractor FB 58
(2682)
S00
(B153)
U683
x value for root function and gradient
(2683)
S00
Definition of input values
(B153)
i001:
Distance between input value of root function and fictitious
passage through zero for y value U684.001
i002:
x value of gradient for y value U684.002
U684
y value for root function and gradient
(2684)
S00
Definition of output values
(B153)
i001:
y value of root function for distance U683.001
i002:
y value of gradient for x value U683.002
11-134
Value range
[Unit]
All connector
FB 54
[SW 2.0 and later]
numbers
1
-32768 to 32767
FB 54
[SW 2.0 and later]
1
0 to 1
1
[SW 2.1 and later]
FB 58
All connector
numbers
[SW 2.0 and later]
1
1 to 65535
1
FB 58
[SW 2.0 and later]
1 to 65535
[SW 2.0 and later]
1
FB 58
1 to 65535
1
[SW 2.0 and later]
FB 58
0.01 to 199.99
[%]
[SW 2.0 and later]
0.01
No. indices
Ind: none
FS=9474
Type: L2
Ind: 8
FS=0
Type: I2
Ind: none
FS=0
Type: O2
Ind: none
FS=9483
Type: L2
Ind: none
FS=1
Type: O2
Ind: none
FS=1
Type: O2
Ind: 2
FS=1000
Type: O2
Ind: 2
FS=100.00
Type: O2
SIEMENS AG
6SG7000-0BA76
SIMOTRAS HD
Operating Instructions
01.04
See
Change
P052 = 2
P051 = 40
Offline
P052 = 2
P051 = 40
Offline
P052 = 2
P051 = 40
online
P052 = 2
P051 = 40
Offline
P052 = 2
P051 = 40
Online
P052 = 2
P051 = 40
Online
P052 = 2
P051 = 40
Online
P052 = 2
P051 = 40
Online