Parameter list
PNU
Description
U207
Settable operating point for limit-value monitor
(2207)
Applied to connector K9189
S00
(B137)
U208
Hysteresis for 4
(2208)
S00
(B137)
U210
Source for input signal (A) and operating point (B) for
(2210)
5. Limit-value monitor without filter
*
i001:
Input signal
S00
i002:
Operating point
(B138)
Settings:
0 = connector K0000
1 = connector K0001
etc.
U211
Settable operating point for limit-value monitor
(2211)
Applied to connector K9190
S00
(B138)
U212
Hysteresis for 5
(2212)
S00
(B138)
U213
Source for input signal (A) and operating point (B) for
(2213)
6. Limit-value monitor without filter
*
i001:
Input signal
S00
i002:
Operating point
(B138)
Settings:
0 = connector K0000
1 = connector K0001
etc.
U214
Settable operating point for limit-value monitor
(2214)
Applied to connector K9191
S00
(B138)
U215
Hysteresis for 6
(2215)
S00
(B138)
U216
Source for input signal (A) and operating point (B) for
(2216)
7. Limit-value monitor without filter
*
i001:
Input signal
S00
i002:
Operating point
(B138)
Settings:
0 = connector K0000
1 = connector K0001
etc.
U217
Settable operating point for limit-value monitor
(2217)
Applied to connector K9192
S00
(B138)
U218
Hysteresis for 7
(2218)
S00
(B138)
11-94
th
limit-value monitor without filtering
th
limit-value monitor without filtering
th
limit-value monitor without filtering
th
limit-value monitor without filtering
Value range
[Unit]
-200.00 to 199.99
FB 76
[%]
0.01%
FB 76
0.00 to 100.00
[%]
0.01%
All connector
FB 77
numbers
1
FB 77
-200.00 to 199.99
[%]
0.01%
FB 77
0.00 to 100.00
[%]
0.01%
FB 78
All connector
numbers
1
-200.00 to 199.99
FB 78
[%]
0.01%
FB 78
0.00 to 100.00
[%]
0.01%
All connector
FB 79
numbers
1
FB 79
-200.00 to 199.99
[%]
0.01%
FB 79
0.00 to 100.00
[%]
0.01%
SIEMENS AG
SIMOTRAS HD
01.04
No. indices
See
Change
Ind: None
P052 = 3
FS=0.00
P051 = 40
Type: I2
Offline
Ind: None
P052 = 3
FS=0.00
P051 = 40
Type: O2
Offline
Ind: 2
P052 = 3
FS=
P051 = 40
i001: 0
Offline
i002: 9190
Type: L2
Ind: None
P052 = 3
FS=0.00
P051 = 40
Type: I2
Offline
Ind: None
P052 = 3
FS=0.00
P051 = 40
Type: O2
Offline
Ind: 2
P052 = 3
FS=
P051 = 40
i001: 0
Offline
i002: 9191
Type: L2
Ind: None
P052 = 3
FS=0.00
P051 = 40
Type: I2
Offline
Ind: None
P052 = 3
FS=0.00
P051 = 40
Type: O2
Offline
Ind: 2
P052 = 3
FS=
P051 = 40
i001: 0
Offline
i002: 9192
Type: L2
Ind: None
P052 = 3
FS=0.00
P051 = 40
Type: I2
Offline
Ind: None
P052 = 3
FS=0.00
P051 = 40
Type: O2
Offline