Parameter list
PNU
Description
P375
OFF delay for n < n comp. signal
FDS
(G187)
Setpoint/actual value deviation 2
P376
Permissible setpoint/actual value deviation 2
FDS
(G187)
P377
Hysteresis for setpoint/actual value deviation 2 signal
FDS
This value is added to the response threshold if a setpoint/actual value
(G187)
deviation signal is active
P378
Response delay for setpoint/actual value deviation signal 2
FDS
(G187)
Overspeed
P380
Maximum speed in positive direction of rotation
FDS
(G188)
P381
Maximum speed in negative direction of rotation
FDS
(G188)
Setpoint/actual value deviation
P387
OFF delay
If the system leaves the state "Setpoint in the controlled range", the system
FDS
waits for the time set here until the setpoint/actual value comparison for the
(G187)
"setpoint/actual deviation" signal (status word 1 bit 8)becomes active again
P388
Permissible deviation between setpoint and actual value
FDS
(G187)
P389
Hysteresis for setpoint/actual value deviation signal
FDS
This value is added to the response threshold if a setpoint/actual value
(G187)
deviation signal is active
P390
Response delay for setpoint/actual value deviation signal
FDS
(G187)
11.17 Settable fixed values
Function: The value set in the parameter is applied to the specified connector
P401
K401 fixed value
FDS
is applied to connector K0401
(G120)
P402
K402 fixed value
FDS
is applied to connector K0402
(G120)
P403
K403 fixed value
FDS
is applied to connector K0403
(G120)
P404
K404 fixed value
FDS
is applied to connector K0404
(G120)
P405
K405 fixed value
FDS
is applied to connector K0405
(G120)
P406
K406 fixed value
FDS
is applied to connector K0406
(G120)
11-30
Value range
[Unit]
0.0 to 100.0
[s]
0.1s
[SW 1.9 and later]
0.00 to 199.99
[%]
0.01% of maximum
speed
0.00 to 199.99
[%]
[SW 1.9 and later]
0.01% of maximum
speed
0.0 to 100.0
[s]
[SW 1.9 and later]
0.1s
0.0 to 199.9
[%]
0.1% of maximum
speed
-199.9 to 0.0
[%]
0.1% of maximum
speed
0.0 to 100.0
[s]
0.1s
0.00 to 199.99
[%]
0.01% of maximum
speed
0.00 to 199.99
[%]
0.01% of maximum
speed
0.0 to 100.0
[s]
0.1s
-199.99 to 199.99
[%]
0.01%
-199.99 to 199.99
[%]
0.01%
-199.99 to 199.99
[%]
0.01%
-199.99 to 199.99
[%]
0.01%
-199.99 to 199.99
[%]
0.01%
-199.99 to 199.99
[%]
0.01%
No. indices
Ind: 4
FS=3.0
Type: O2
Ind: 4
FD=3.00
Type: O2
Ind: 4
FS=1.00
Type: O2
Ind: 4
FS=3.0
Type: O2
Ind: 4
FS=120.0
Type: O2
Ind: 4
FS=-120.0
Type: I2
Ind: 4
FS=2.0
Type: O2
Ind: 4
FS=5.00
Type: O2
Ind: 4
FS=1.00
Type: O2
Ind: 4
FS=1.0
Type: O2
Ind: 4
FS=60.00
Type: I2
Ind: 4
FS=0.00
Type: I2
Ind: 4
FS=0.00
Type: I2
Ind: 4
FS=0.00
Type: I2
Ind: 4
FS=0.00
Type: I2
Ind: 4
FS=0.00
Type: I2
SIEMENS AG
6SG7000-0BA76
SIMOTRAS HD
Operating Instructions
01.04
See
Change
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Online

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents