Siemens SIMOTRAS 6SG7050 Operating Instructions Manual page 478

6sg70 series
Table of Contents

Advertisement

Parameter list
PNU
Description
U627
Filter time for actual speed value for switch over of rotor stages
(2627)
FDS
(G119)
U628
Threshold for "Setpoint in the controlled range" signal
(2628)
FDS
(G136)
(G160)
U629
Hysteresis for "Setpoint in the controlled range" signal
(2629)
FDS
(G136)
11.72 Rotor stage stepping
U630
Setpoint for premature switch over to controlled torque characteristic
(2630)
– MI
FDS
(G119)
U631
Hysteresis for premature switch over to controlled torque
(2631)
characteristic – MI
FDS
(G119)
U632
Setpoint for premature switch over to controlled torque characteristic
(2632)
– MII
FDS
(G119)
U633
Hysteresis for premature switch over to controlled torque
(2633)
characteristic – MII
FDS
(G119)
U634
Threshold for switch over to rotor contactor stage 2
(2634)
Switching of rotor contactor 2 when specified actual speed value reaches
FDS
the controlled range
(G119)
U635
Hysteresis for switch over to rotor contactor stage 2
(2635)
FDS
(G119)
U636
Threshold for switch over to rotor contactor stage 3
(2636)
Switching of rotor contactor 3 when specified actual speed value reaches
FDS
the controlled range
(G119)
U637
Hysteresis for switch over to rotor contactor stage 3
(2637)
FDS
(G119)
U638
Threshold for switch over to rotor contactor stage 4
(2638)
Switching of rotor contactor 4 when specified actual speed value reaches
FDS
the controlled range
(G119)
U639
Hysteresis for switch over to rotor contactor stage 4
(2639)
FDS
(G119)
11-130
Value range
No. indices
[Unit]
0 to 10000
Ind: 4
[ms]
FS=0
1ms
Type: O2
10.0 to 199.9
Ind: 4
[%]
FS=-55.0
0.1%
Type: O2
0.1 to 10.0
Ind: 4
[%]
FS=5.0
0.1%
Type: O2
0.0 to -100.0
Ind: 4
[%]
FS=-1.0
0.1%
Type: I2
0.1 to 10.0
Ind: 4
[%]
FS=5.0
0.1%
Type: O2
0.0 to 100.0
Ind: 4
[%]
FS=1.0
0.1%
Type: O2
0.1 to 10.0
Ind: 4
[%]
FS=5.0
0.1%
Type: O2
10.0 to 100.0
Ind: 4
[%]
FS=50.0
0.1%
Type: O2
0.1 to 50.0
Ind: 4
[%]
FS=5.0
0.1%
Type: O2
10.0 to 100.0
Ind: 4
[%]
FS=75.0
0.1%
Type: O2
0.1 to 50.0
Ind: 4
[%]
FS=5.0
0.1%
Type: O2
10.0 to 100.0
Ind: 4
[%]
FS=90.0
0.1%
Type: O2
0.1 to 50.0
Ind: 4
[%]
FS=5.0
0.1%
Type: O2
SIEMENS AG
SIMOTRAS HD
Operating Instructions
01.04
See
Change
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Online
6SG7000-0BA76

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents