Siemens SIMOTRAS 6SG7050 Operating Instructions Manual page 536

6sg70 series
Table of Contents

Advertisement

Connectors and binectors
Binector
Name, description
B0149
Stat.word 2, bit 24 inverted
B0150
Stat.word 2, bit 25: 0=no motor overtemperature alarm active, 1=motor overtemperature alarm active
Stat.word 2, bit 25 inverted
B0151
B0152
Stat.word 2, bit 26: 0=no motor overtemperature fault active, 1=motor overtemperature fault active
Stat.word 2, bit 26 inverted
B0153
B0156
Stat.word 2, bit 28: 0=no motor blocked fault active, 1=motor blocked fault active
Messages
0=AUS1 or AUS3 active, 1=no AUS1 and no AUS3 is pending
B0160
B0161
B0160 inverted
1 = n < n
B0164
min
B0165
B0164 inverted
1 = Voltage at power section is active
B0166
B0167
B0166 inverted
1=Voltage at power section AND operating state <= o7
B0170
B0171
B0170 inverted
Output of "Setpoint-actual value deviation 2" signal
B0172
B0173
B0172 inverted
Acknowledgement of fault codes
Acknowledgement of control word or P key on PMU (pulse)
B0179
Binary inputs
B0180
1=Terminal 211 not activated for more than 10 s.
1=Terminal 212 activated for more than 2 s.
B0181
B0182
1=Terminal 213 not activated for more than 40 s while in operating state < o6
1=Terminal 214 not activated for more than 10 s.
B0183
Temperature sensor inputs
B0184
1=Alarm motor temperature 1
1=Alarm motor temperature 2
B0185
Alarm messages
1=Alarm A037 (I2t motor) active
B0186
B0187
1=Alarm A039 (I2t power section) active
1=Alarm A067 (heatsink temperature) active
B0188
B0189
1=Alarm A067 (converter fan) active
Torque limitation, current limitation, current controller
B0190
0 = pulsating current, 1 = continuous current
Speed limitation controller: Positive speed limit reached
B0192
B0193
Speed limitation controller: Negative speed limit reached
B0194
Current limitation: Positive current limit reached
B0195
Current limitation: Negative current limit reached
B0198
Any positive limit (speed, torque, current) reached
Any positive limit (speed, torque, current) reached
B0199
B0200
Current limitation active
Speed limiting controller active
B0201
B0202
Upper torque limitation active
12-26
Function
diag., Sheet
G183
G183
G183
G183
G183
G183
G180
G180
G188
G188
G119
G119
[SW 1.9 and later]
G187
[SW 1.9 and later]
G187
[SW 2.1 and later]
G180
G186
G186
G186
G186
G185
G185
[SW 2.0 and later]
G162
[SW 1.8 and later]
G160
[SW 1.8 and later]
G160
[SW 1.8 and later]
G161
[SW 1.8 and later]
G161
[SW 2.0 and later]
[SW 2.0 and later]
G161
G160
G160
SIEMENS AG
6SG7000-0BA76
SIMOTRAS HD
Operating Instructions
01.04

Hide quick links:

Advertisement

Table of Contents
loading