6. Install the heat sink onto the microprocessor as described in "Replacing the

Installing the non-hot-swap power supply

This procedure applies only to 4U server models with non-hot-swap power
supplies.
Statement 8
CAUTION:
Never remove the cover on a power supply or any part that has the following
label attached.
Hazardous voltage, current, and energy levels are present inside any component
that has this label attached. There are no serviceable parts inside these
components. If you suspect a with one of these parts, contact a service
technician.
To install a non-hot-swap power supply on 4U server models with non-hot-swap
power supplies, complete the following steps.
1. Read the safety information in "Safety" on page vii and "Installation
2. Touch the static-protective package that contains the non-hot-swap power
3. Turn off the server and all attached devices; then, disconnect all power cords
4. Carefully turn the server on its side so that it is lying flat, with the cover facing
5. Remove the side cover (see "Removing the side cover" on page 38).
6. Remove the air baffle (see "Removing the air baffle" on page 39).
7. Remove the heat sink (see "Removing the microprocessor and heat sink" on
72
System x3100 M5 Type 5457: Installation and Service Guide
microprocessor and heat sink" on page 304.
guidelines" on page 35.
supply to any unpainted metal surface on the server; then, remove the power
supply from the package and place it on a static-protective surface.
and external cables.
up.
Attention: Do not allow the server to fall over.
page 300).