Incorrect
To remove a DVD drive in the 5U server model with hot-swap power supplies,
complete the following steps. For 4U server models with non-hot-swap power
supplies, please see the above sub-section.
1. Read the safety information in "Safety" on page vii and "Installation
guidelines" on page 35.
2. Turn off the server and all attached devices; then, disconnect all power cords
and external cables.
3. Unlock and remove the side cover (see "Removing the side cover" on page 38).
4. Remove the lower bezel (see "Removing the lower bezel" on page 42).
5. Remove the upper bezel (see "Removing the upper bezel" on page 43).
6. Disconnect the power and signal cables from the drive that is to be removed.
7. Press and hold the blue-colored release button on the side of the bay to release
the drive; then, pull the drive out of the front of the server.
Correct
Chapter 6. Removing and replacing components
Filler Panel
205