806f072b-2201ffff • 806f0813-2581ffff
806f072b-2201ffff
A successful software or firmware change was detected on system
[ComputerSystemElementName]. (Bkup Auto Update / ROM Recovery)
Explanation: This message is for the use case when an implementation has detected a Successful Software or
Firmware Change.
May also be shown as 806f072b2201ffff or 0x806f072b2201ffff
Severity: Info
Alert Category: System - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0450
SNMP Trap ID:
Automatically notify Support: No
User response: No action; information only.
806f0807-0301ffff
[ProcessorElementName] has been Disabled. (CPU 1)
Explanation: This message is for the use case when an implementation has detected a Processor has been Disabled.
May also be shown as 806f08070301ffff or 0x806f08070301ffff
Severity: Info
Alert Category: System - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0061
SNMP Trap ID:
Automatically notify Support: No
User response: No action; information only.
806f0813-2581ffff
A Uncorrectable Bus Error has occurred on system [ComputerSystemElementName]. (DIMMs)
Explanation: This message is for the use case when an implementation has detected a Bus Uncorrectable Error.
May also be shown as 806f08132581ffff or 0x806f08132581ffff
Severity: Error
Alert Category: Critical - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0240
SNMP Trap ID: 50
Automatically notify Support: Yes
User response:
1.
Check the system-event log.
2.
Check the DIMM error LEDs.
3.
Remove the failing DIMM from the system board.
4.
Check for a server firmware update. Important: Some cluster solutions require specific code levels or coordinated
code updates. If the device is part of a cluster solution, verify that the latest level of code is supported for the
cluster solution before you update the code.
5.
Make sure that the installed DIMMs are supported and configured correctly.
6.
(Trained technician only) Replace the system board.