IBM x3100 M5 Type 5457 Installation And Service Manual page 448

Hide thumbs Also See for x3100 M5 Type 5457:
Table of Contents

Advertisement

806f050d-0400ffff • 806f050d-0401ffff
3.
If the problem follows the DIMM, replace the failing DIMM.
4.
(Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the
connector contains any foreign material or is damaged, replace the system board.
5.
(Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any
damaged pins. If a damage is found, replace the system board.
6.
(Trained technician only) Replace the affected microprocessor.
Manually re-enable all affected DIMMs if the server firmware version is older than UEFI v1.10. If the server
7.
firmware version is UEFI v1.10 or newer, disconnect and reconnect the server to the power source and restart the
server.
8.
(Trained Service technician only) Replace the affected microprocessor.
806f050d-0400ffff
Array [ComputerSystemElementName] is in critical condition. (Drive 0)
Explanation: This message is for the use case when an implementation has detected that an Array is Critical.
May also be shown as 806f050d0400ffff or 0x806f050d0400ffff
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0174
SNMP Trap ID: 5
Automatically notify Support: No
User response:
1.
Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2.
Make sure that the SAS cable is connected correctly.
3.
Replace the SAS cable.
4.
Check backplane cable connection.
5.
Replace the RAID adapter.
Replace the hard disk drive that is indicated by a lit status LED.
6.
806f050d-0401ffff
Array [ComputerSystemElementName] is in critical condition. (Drive 1)
Explanation: This message is for the use case when an implementation has detected that an Array is Critical.
May also be shown as 806f050d0401ffff or 0x806f050d0401ffff
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0174
SNMP Trap ID: 5
Automatically notify Support: No
User response:
1.
Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2.
Make sure that the SAS cable is connected correctly.
3.
Replace the SAS cable.
4.
Check backplane cable connection.
Replace the RAID adapter.
5.
Replace the hard disk drive that is indicated by a lit status LED.
6.
432
System x3100 M5 Type 5457: Installation and Service Guide