IBM x3100 M5 Type 5457 Installation And Service Manual page 465

Hide thumbs Also See for x3100 M5 Type 5457:
Table of Contents

Advertisement

806f090c-2003ffff
[PhysicalMemoryElementName] on Subsystem [MemoryElementName] Throttled. (DIMM 3)
Explanation: This message is for the use case when an implementation has detected Memory has been Throttled.
May also be shown as 806f090c2003ffff or 0x806f090c2003ffff
Severity: Warning
Alert Category: System - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0142
SNMP Trap ID: 22
Automatically notify Support: No
User response:
1.
Reseat the DIMM, and then restart the server.
2.
Replace DIMM n. (n = DIMM number)
806f090c-2004ffff
[PhysicalMemoryElementName] on Subsystem [MemoryElementName] Throttled. (DIMM 4)
Explanation: This message is for the use case when an implementation has detected Memory has been Throttled.
May also be shown as 806f090c2004ffff or 0x806f090c2004ffff
Severity: Warning
Alert Category: System - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0142
SNMP Trap ID: 22
Automatically notify Support: No
User response:
1.
Reseat the DIMM, and then restart the server.
2.
Replace DIMM n. (n = DIMM number)
806f0a07-0301ffff
[ProcessorElementName] is operating in a Degraded State. (CPU 1)
Explanation: This message is for the use case when an implementation has detected a Processor is running in the
Degraded state.
May also be shown as 806f0a070301ffff or 0x806f0a070301ffff
Severity: Warning
Alert Category: Warning - CPU
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0038
SNMP Trap ID: 42
Automatically notify Support: No
User response:
Make sure that the fans are operating, that there are no obstructions to the airflow (front and rear of the server),
1.
that the air baffles are in place and correctly installed, and that the server cover is installed and completely
closed.
Check the ambient temperature. You must be operating within the specifications.
2.
Make sure that the heat sink for microprocessor n is installed correctly.
3.
4.
(Trained technician only) Replace microprocessor n. (n = microprocessor number)
806f090c-2003ffff • 806f0a07-0301ffff
Appendix A. Integrated management module II (IMM2) error messages
449

Advertisement

Table of Contents
loading

Table of Contents