80010901-0703ffff • 80010901-2701ffff
80010901-0703ffff
Numeric sensor [NumericSensorElementName] going high (upper critical) has asserted.
(Ambient1 Temp)
Explanation: This message is for the use case when an implementation has detected an Upper Critical sensor going
high has asserted.
May also be shown as 800109010703ffff or 0x800109010703ffff
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0494
SNMP Trap ID: 0
Automatically notify Support: No
User response:
1.
Make sure that the fans are operating, that there are no obstructions to the airflow (front and rear of the server),
that the air baffle is in place and correctly installed, and that the server cover is installed and completely closed.
2.
Check the ambient temperature. You must be operating within the specifications (see Server Features and
specifications for more information).
3.
Make sure that the heat sink for microprocessor n.
4.
(Trained technician only) Replace system board.
80010901-2701ffff
Numeric sensor [NumericSensorElementName] going high (upper critical) has asserted.
(Ambient2 Temp)
Explanation: This message is for the use case when an implementation has detected an Upper Critical sensor going
high has asserted.
May also be shown as 800109012701ffff or 0x800109012701ffff
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0494
SNMP Trap ID: 0
Automatically notify Support: No
User response:
1.
Make sure that the fans are operating, that there are no obstructions to the airflow (front and rear of the server),
that the air baffle is in place and correctly installed, and that the server cover is installed and completely closed.
2.
Check the ambient temperature. You must be operating within the specifications (see Server Features and
specifications for more information).
3.
Make sure that the heat sink for microprocessor n.
4.
(Trained technician only) Replace system board.