6. If you have other devices to install, do so now. Otherwise, go to "Completing

Installing the battery holder into 5U server model

Use this information to install the battery holder into 5U server model
Attention: To ensure proper cooling and airflow, do not operate the server for
more than 30 minutes with the side cover removed.
To install the battery holder into 5U server models with hot-swap power supplies,
complete the following steps.
1. Read the safety information in "Safety" on page vii and "Installation
2. Turn off the server and all attached devices; then, disconnect all power cords
3. Unlock and remove the side cover (see "Removing the side cover" on page 38).
4. Carefully turn the server on its side so that it is lying flat, with the cover facing
78
System x3100 M5 Type 5457: Installation and Service Guide
a. Position the fan so that the grommets protrude through the holes in the
chassis; then, use needle-nosed pliers to pull the grommets through the
holes from outside the chassis.
b. Connect the fan cable into the system board (see "System-board internal
connectors" on page 30).
the installation" on page 82.
guidelines" on page 35.
and external cables.
up.
Attention: Do not allow the server to fall over.