IBM x3100 M5 Type 5457 Installation And Service Manual page 416

Hide thumbs Also See for x3100 M5 Type 5457:
Table of Contents

Advertisement

806f000d-0406ffff • 806f000f-220101ff
806f000d-0406ffff
The Drive [StorageVolumeElementName] has been added. (Drive 6)
Explanation: This message is for the use case when an implementation has detected a Drive has been Added.
May also be shown as 806f000d0406ffff or 0x806f000d0406ffff
Severity: Info
Alert Category: Critical - Hard Disk drive
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0162
SNMP Trap ID: 5
Automatically notify Support: No
User response: No action; information only.
806f000d-0407ffff
The Drive [StorageVolumeElementName] has been added. (Drive 7)
Explanation: This message is for the use case when an implementation has detected a Drive has been Added.
May also be shown as 806f000d0407ffff or 0x806f000d0407ffff
Severity: Info
Alert Category: Critical - Hard Disk drive
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0162
SNMP Trap ID: 5
Automatically notify Support: No
User response: No action; information only.
806f000f-220101ff
The System [ComputerSystemElementName] has detected no memory in the system. (ABR
Status)
Explanation: This message is for the use case when an implementation has detected that memory was detected in
the system.
May also be shown as 806f000f220101ff or 0x806f000f220101ff
Severity: Error
Alert Category: Critical - Memory
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0794
SNMP Trap ID: 41
Automatically notify Support: No
User response:
1.
Make sure the server meets the minimum configuration to start (see Power-supply LEDs).
2.
Recover the server firmware from the backup page: a. Restart the server. b. At the prompt, press F3 to recover
the firmware.
3.
Update the server firmware on the primary page. Important: Some cluster solutions require specific code levels
or coordinated code updates. If the device is part of a cluster solution, verify that the latest level of code is
supported for the cluster solution before you update the code.
4.
Remove components one at a time, restarting the server each time, to see if the problem goes away.
5.
If the problem remains, (trained technician only) replace the system board.
400
System x3100 M5 Type 5457: Installation and Service Guide

Advertisement

Table of Contents
loading