Removing The Thermal Solution Fan Kit - IBM x3100 M5 Type 5457 Installation And Service Manual

Hide thumbs Also See for x3100 M5 Type 5457:
Table of Contents

Advertisement

6. Install the air baffle (see "Replacing the air baffle" on page 185).
7. Install the side cover (see "Replacing the side cover" on page 182).
8. Stand the server back up in its vertical position.
9. Reconnect the external cables and power cords; then, turn on the attached

Removing the thermal solution fan kit

Use this information to remove the thermal solution fan kit
To remove the thermal solution fan kit on the 4U server model with non-hot-swap
power supplies, complete the following steps. For 5U server models with hot-swap
power supplies, please see the next sub-section.
1. Read the safety information in "Safety" on page vii and "Installation
2. Turn off the server and all attached devices; then, disconnect all power cords
3. Carefully turn the server on its side so that it is lying flat, with the cover facing
4. Remove the side cover (see "Removing the side cover" on page 38).
5. Remove the air baffle (see "Removing the air baffle" on page 39).
6. Remove the thermal solution fan kit:
Figure 199. Thermal solution fan kit removal for 4U server model with non-hot-swap power
supplies
7. If you are instructed to return the thermal solution fan kit, follow all packaging
286
System x3100 M5 Type 5457: Installation and Service Guide
devices and turn on the server.
guidelines" on page 35.
and external cables.
up.
Attention: Do not allow the server to fall over.
Thermal solution
2
fan kit
3
1
a. Disconnect the fan cable from the system board (see "System-board internal
connectors" on page 30).
b. While you support the system fan with one hand, pull the rubber grommet
away from the chassis to make it thinner; then, pull the fan toward the front
of the server to remove the rubber grommet through the hole on the
chassis. Repeat this step till all the remaining rubber grommets are
removed.
c. Lift the system fan up and out of the chassis.
instructions, and use any packaging materials for shipping that are supplied to
you.
Second fan
power connector