IBM x3100 M5 Type 5457 Installation And Service Manual page 525

Hide thumbs Also See for x3100 M5 Type 5457:
Table of Contents

Advertisement

8.
(Trained service technician only) Replace the system board.
S.68005
[S.68005] An error has been detected by the the IIO core logic on Bus %. The Global Fatal Error
Status register contains %. The Global Non-Fatal Error Status register contains %. Please check error
logs for the presence of additional downstream device error data.
Explanation: Critical IOH-PCI Error
Severity: Error
User response: Complete the following steps:
1.
Check log for a separate error for an associated PCIe device and service that error.
2.
Check IBM Support website for an applicable service bulletin or firmware update for the system or adapter that
applies to this error.
3.
(Trained service technician only) Replace the system board.
W.11004
[W.11004] A processor within the system has failed the BIST.
Explanation: Processor Self Test Failure Detected
Severity: Warning
User response: Complete the following steps:
1.
If the Processor or firmware was just updated, check IBM Support website for an applicable service bulletin or
firmware update that applies to this Processor error.
2.
(Trained service technician only) If there are multiple Processor's, swap Processor's to move affected Processor to
another Processor socket and retry. If problem follows the affected Processor, or this is a single Processor system,
replace the Processor. Inspect Processor socket on each Processor removal and replace system board first if
damaged or mis-aligned pins are found.
3.
(Trained service technician only) Replace the system board.
W.3048006
[W.3048006] UEFI has booted from the backup flash bank due to an Automatic Boot Recovery (ABR)
event.
Explanation: Automated Boot Recovery, Booting Backup UEFI Image
Severity: Warning
User response: Complete the following steps:
1.
Check IBM Support website for an applicable service bulletin or firmware update that applies to this error.
2.
Reflash Primary UEFI image. Refer to UEFI Recovery section of service information for this product.
3.
(Trained service technician only) Replace the system board.
S.68005 • W.3048006
Appendix B. UEFI/POST diagnostic codes
509