806f0023-2101ffff • 806f0108-0a01ffff
806f0023-2101ffff
Watchdog Timer expired for [WatchdogElementName]. (IPMI Watchdog)
Explanation: This message is for the use case when an implementation has detected a Watchdog Timer Expired.
May also be shown as 806f00232101ffff or 0x806f00232101ffff
Severity: Info
Alert Category: System - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0368
SNMP Trap ID:
Automatically notify Support: No
User response: No action; information only.
806f0107-0301ffff
An Over-Temperature Condition has been detected on [ProcessorElementName]. (CPU 1)
Explanation: This message is for the use case when an implementation has detected an Over-Temperature Condition
Detected for Processor.
May also be shown as 806f01070301ffff or 0x806f01070301ffff
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0036
SNMP Trap ID: 0
Automatically notify Support: No
User response:
Make sure that the fans are operating. There are no obstructions to the airflow (front and rear of the server), the
1.
air baffles are in place and correctly installed, and the server cover is installed and completely closed.
2.
Make sure that the heat sink for microprocessor n is installed correctly.
3.
(Trained technician only) Replace microprocessor n. (n = microprocessor number)
806f0108-0a01ffff
[PowerSupplyElementName] has Failed. (Power Supply 1)
Explanation: This message is for the use case when an implementation has detected a Power Supply has failed.
May also be shown as 806f01080a01ffff or 0x806f01080a01ffff
Severity: Error
Alert Category: Critical - Power
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0086
SNMP Trap ID: 4
Automatically notify Support: Yes
User response:
1.
Reseat power supply n.
If the power-on LED is not lit and the power-supply error LED is lit, replace power supply n.
2.
If both the power-on LED and the power-supply error LED are not lit, see Power problems for more information.
3.
(n = power supply number)