806f0021-3001ffff • 806f0021-3002ffff
806f0021-3001ffff
Fault in slot [PhysicalConnectorSystemElementName] on system
[ComputerSystemElementName]. (PCI 1)
Explanation: This message is for the use case when an implementation has detected a Fault in a slot.
May also be shown as 806f00213001ffff or 0x806f00213001ffff
Severity: Error
Alert Category: Critical - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0330
SNMP Trap ID: 50
Automatically notify Support: Yes
User response:
1.
Check the PCI LED.
2.
Reseat the affected adapters and riser card.
3.
Update the server firmware (UEFI and IMM) and adapter firmware. Important: Some cluster solutions require
specific code levels or coordinated code updates. If the device is part of a cluster solution, verify that the latest
level of code is supported for the cluster solution before you update the code.
4.
Replace the affected adapters.
5.
Replace the riser card.
(Trained service technicians only) Replace the system board.
6.
806f0021-3002ffff
Fault in slot [PhysicalConnectorSystemElementName] on system
[ComputerSystemElementName]. (PCI 2)
Explanation: This message is for the use case when an implementation has detected a Fault in a slot.
May also be shown as 806f00213002ffff or 0x806f00213002ffff
Severity: Error
Alert Category: Critical - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0330
SNMP Trap ID: 50
Automatically notify Support: Yes
User response:
1.
Check the PCI LED.
2.
Reseat the affected adapters and riser card.
3.
Update the server firmware (UEFI and IMM) and adapter firmware. Important: Some cluster solutions require
specific code levels or coordinated code updates. If the device is part of a cluster solution, verify that the latest
level of code is supported for the cluster solution before you update the code.
4.
Replace the affected adapters.
5.
Replace the riser card.
6.
(Trained service technicians only) Replace the system board.
406
System x3100 M5 Type 5457: Installation and Service Guide