IBM x3100 M5 Type 5457 Installation And Service Manual page 631

Hide thumbs Also See for x3100 M5 Type 5457:
Table of Contents

Advertisement

201-878-003
Standalone Memory Test Aborted
Explanation: Sparing feature must be turned OFF. Go to setup and turn the sparing feature OFF.
Severity: Warning
Serviceable: No
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related Links:
IBM Support Website
v
Latest level of DSA
v
Latest level of BMC/IMM
v
201-885-000
Standalone Memory Test Aborted
Explanation: Processor does not support MTRR register manipulation. Can not write to memory without cache.
Severity: Warning
Serviceable: No
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related Links:
v
IBM Support Website
Latest level of DSA
v
Latest level of BMC/IMM
v
201-878-003 • 201-885-000
Appendix C. DSA diagnostic test results
615

Advertisement

Table of Contents
loading