IBM x3100 M5 Type 5457 Installation And Service Manual page 293

Hide thumbs Also See for x3100 M5 Type 5457:
Table of Contents

Advertisement

PCI slot 1
PCI slot 2
PCI slot 3
PCI slot 4
Fan 2 connector
USB hypervisor
connector
USB tape drive
connector
Front USB
connector
SATA5
SATA4
SATA3
Operator information
panel connector
Figure 189. DIMM connectors on system board
Attention: Static electricity that is released to internal server components when
the server is powered on might cause the server to halt, which might result in the
loss of data. To avoid this potential problem, always use an electrostatic-discharge
wrist strap or other grounding system when you work inside the server with the
power on.
To install a DIMM on 4U server models with non-hot-swap power supplies,
complete the following steps. For the 5U server model with hot-swap power
supplies, please see the next sub-section.
1. Read the safety information in "Safety" on page vii and "Installation
guidelines" on page 35.
2. Locate the DIMM connectors on the system board. Determine the connectors
into which you will install the DIMMs. Install the DIMMs in the sequence
shown in the following table.
Table 38. DIMM installation sequence
Number of DIMMs
First pair of DIMMs
Second pair of DIMMs
3. Open the retaining clips and, if necessary, remove any existing DIMM.
Attention: To avoid breaking the retaining clips or damaging the DIMM
connectors, open and close the clips gently.
Microprocessor
power connector
Fan 1 connector
Microprocessor
SATA2 SATA1 SATA0
Installation sequence (connectors)
1, 3
2, 4
Chapter 6. Removing and replacing components
Power supply
connector
Thermal
sensor
connector
HDD backplane
power connector
Battery
277

Advertisement

Table of Contents
loading

Table of Contents