816f000d-0400ffff
The Drive [StorageVolumeElementName] has been removed from unit
[PhysicalPackageElementName]. (Drive 0)
Explanation: This message is for the use case when an implementation has detected a Drive has been Removed.
May also be shown as 816f000d0400ffff or 0x816f000d0400ffff
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0163
SNMP Trap ID: 5
Automatically notify Support: No
User response:
1.
Reseat hard disk drive n.(n = hard disk drive number). Wait 1 minute or more before reinstalling the drive.
2.
Make sure that the disk firmware and RAID controller and backplane firmware are at the latest level.
3.
Check the SAS cable.
Replace the hard disk drive.
4.
816f000d-0401ffff
The Drive [StorageVolumeElementName] has been removed from unit
[PhysicalPackageElementName]. (Drive 1)
Explanation: This message is for the use case when an implementation has detected a Drive has been Removed.
May also be shown as 816f000d0401ffff or 0x816f000d0401ffff
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0163
SNMP Trap ID: 5
Automatically notify Support: No
User response:
1.
Reseat hard disk drive n.(n = hard disk drive number). Wait 1 minute or more before reinstalling the drive.
2.
Make sure that the disk firmware and RAID controller and backplane firmware are at the latest level.
3.
Check the SAS cable.
4.
Replace the hard disk drive.
816f000d-0400ffff • 816f000d-0401ffff
Appendix A. Integrated management module II (IMM2) error messages