80010202-0701ffff
Numeric sensor [NumericSensorElementName] going low (lower critical) has asserted. (CMOS
Battery)
Explanation: This message is for the use case when an implementation has detected a Lower Critical sensor going
low has asserted.
May also be shown as 800102020701ffff or 0x800102020701ffff
Severity: Error
Alert Category: Critical - Voltage
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0480
SNMP Trap ID: 1
Automatically notify Support: Yes
User response: If the specified sensor is CMOS battery, replace the system battery. If the specified sensor is Planar
3.3V or Planar 5V, (trained technician only) replace the system board. If the specified sensor is Planar 12V, complete
the following steps until the problem is solved:
1.
Check power supply n LED.
2.
Remove the failing power supply.
3.
Follow actions in "Power Problems and Solving Power Problems".
4.
(Trained technician only) Replace the system board. (n = power supply number)
80010204-1d01ffff
Numeric sensor [NumericSensorElementName] going low (lower critical) has asserted. (Fan 1
Tach)
Explanation: This message is for the use case when an implementation has detected a Lower Critical sensor going
low has asserted.
May also be shown as 800102041d01ffff or 0x800102041d01ffff
Severity: Error
Alert Category: Critical - Fan Failure
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0480
SNMP Trap ID: 11
Automatically notify Support: No
User response:
1.
Reseat the failing fan n, which is indicated by a lit LED near the fan connector on the system board.
2.
Replace the failing fan. (n = fan number)
80010202-0701ffff • 80010204-1d01ffff
Appendix A. Integrated management module II (IMM2) error messages
379