IBM x3100 M5 Type 5457 Installation And Service Manual page 563

Hide thumbs Also See for x3100 M5 Type 5457:
Table of Contents

Advertisement

406-902-000
IANet:FIFO Test Failed
Explanation: A failure was detected during the FIFO test.
Severity: Error
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Check component firmware level and upgrade if necessary. The installed firmware level can be found in the DSA
Diagnostic Event Log within the Firmware/VPD section for this component.
2. Rerun the test.
3. If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service Guide" for the
next corrective action.
Related Links:
IBM Support Website
v
Latest level of DSA
v
Latest level of BMC/IMM
v
406-903-000
IANet:Interrupts Test Failed
Explanation: A failure was detected during the Interrupt test.
Severity: Error
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Check component firmware level and upgrade if necessary. The installed firmware level can be found in the DSA
Diagnostic Event Log within the Firmware/VPD section for this component.
2. Rerun the test.
3. Check interrupt assignments in the PCI Hardware section of the DSA Diagnostic Log. If the ethernet device is
sharing interrupts, if possible modify the interrupt assignments using F1 Setup to assign a unique interrupt to the
device.
4. Rerun the test.
5. If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service Guide" for the
next corrective action.
Related Links:
IBM Support Website
v
Latest level of DSA
v
Latest level of BMC/IMM
v
406-902-000 • 406-903-000
Appendix C. DSA diagnostic test results
547

Advertisement

Table of Contents
loading

Table of Contents