80010204-1d02ffff • 80010701-0701ffff
80010204-1d02ffff
Numeric sensor [NumericSensorElementName] going low (lower critical) has asserted. (Fan 2
Tach)
Explanation: This message is for the use case when an implementation has detected a Lower Critical sensor going
low has asserted.
May also be shown as 800102041d02ffff or 0x800102041d02ffff
Severity: Error
Alert Category: Critical - Fan Failure
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0480
SNMP Trap ID: 11
Automatically notify Support: No
User response:
1.
Reseat the failing fan n, which is indicated by a lit LED near the fan connector on the system board.
2.
Replace the failing fan. (n = fan number)
80010701-0701ffff
Numeric sensor [NumericSensorElementName] going high (upper non-critical) has asserted.
(PCI Temp)
Explanation: This message is for the use case when an implementation has detected an Upper Non-critical sensor
going high has asserted.
May also be shown as 800107010701ffff or 0x800107010701ffff
Severity: Warning
Alert Category: Warning - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0490
SNMP Trap ID: 12
Automatically notify Support: No
User response:
Make sure that the fans are operating, that there are no obstructions to the airflow (front and rear of the server),
1.
that the air baffle is in place and correctly installed, and that the server cover is installed and completely closed.
Check the ambient temperature. You must be operating within the specifications (see Server Features and
2.
specifications for more information).
3.
Make sure that the heat sink for microprocessor n.
4.
(Trained technician only) Replace system board.