215-803-000
Optical Drive Test Failed
Explanation: Optical Drive Test Failed. Disk may be in use by the operating system.
Severity: Error
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Wait for the system activity to cease
2. Run the test again
3. Turn off and restart the system.
4. Run the test again.
Related Links:
IBM Support Website
v
Latest level of DSA
v
Latest level of BMC/IMM
v
215-804-000
Optical Drive Test Aborted
Explanation: Optical Drive Test Aborted. The media tray is open.
Severity: Warning
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Close the media tray and wait for 15 seconds for the media to be recognized. Run the test again.
2. Insert a new CD or DVD into the drive and wait for 15 seconds for the media to be recognized. Rerun the test.
3. Check the drive cabling for loose or broken connections at both ends or damage to the cable. Replace the cable if
damage is present.
4. Run the test again.
5. If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service Guide" for the
next corrective action.
Related Links:
v
IBM Support Website
v
Latest level of DSA
Latest level of BMC/IMM
v
215-803-000 • 215-804-000