IBM x3100 M5 Type 5457 Installation And Service Manual page 147

Hide thumbs Also See for x3100 M5 Type 5457:
Table of Contents

Advertisement

Fault (error)LED (yellow)
Figure 72. LEDs and connectors on the rear of the 5U server model with hot-swap power
supplies
The following table describes the problems that are indicated by various
combinations of the power-supply LEDs and suggested actions to correct the
detected problems.
Table 11. Power-supply LEDs
AC Power-supply LEDs
AC
DC
Error
On
On
Off
Off
Off
Off
On
Off
Off
AC Power LED (green)
DC power LED (green)
Serial (Com1)
Video
USB connectors
Description
Normal
operation
No ac power to
the server or a
problem with the
ac power source.
Faulty system
board or faulty
power supply
Power connectors
Action
1. Check the ac power to the server.
2. Make sure that the power cord is
connected to a functioning power
source.
3. Restart the server. If the error remains,
check the power-supply LEDs.
4. If the problem remains, replace the
power-supply.
1. Turn off the server and disconnect the
power cord from the server; then,
reconnect the power cord.
2. If the system board error (fault) LED
is not lit, replace the power supply.
3. (Trained technician only) If the system
board error LED is lit, replace the
system board.
Ethernet
connector 1
Ethernet
connector 2
Ethernet link
status LED
Ethernet transmit/
receive activity LED
Notes
This is a normal
condition when no
ac power is present.
Typically indicates
that a power supply
is not fully seated.
This is a normal
condition before
turning on the
system.
Chapter 4. Troubleshooting
131

Advertisement

Table of Contents
loading