IBM x3100 M5 Type 5457 Installation And Service Manual page 520

Hide thumbs Also See for x3100 M5 Type 5457:
Table of Contents

Advertisement

I.580A4 • S.2018001
I.580A4
[I.580A4] Memory population change detected.
Explanation: DIMM Population Change Detected
Severity: Info
User response: Complete the following steps:
1.
Check system event log for uncorrected DIMM failures and replace those DIMMs.
S.2011001
[S.2011001] An Uncorrected PCIe Error has Occurred at Bus % Device % Function %. The Vendor ID
for the device is % and the Device ID is %.
Explanation: PCI SERR Detected
Severity: Error
User response: Complete the following steps:
1.
If this node and/or any attached cables were recently installed, moved, serviced or upgraded, a. Reseat Adapter
and any attached cables. b. Reload Device Driver c. If device is not recognized, reconfiguring slot to Gen1 or
Gen2 may be required. Gen1/Gen2 settings can be configured via F1 Setup -> System Settings -> Devices and I/O
Ports -> PCIe Gen1/Gen2/Gen3 Speed Selection, or the ASU Utility.
Check IBM Support website for an applicable device driver, firmware update, revision of service information for
2.
this product or other information that applies to this error. Load new device driver and any required firmware
updates.
If problem persists, then remove Adapter Card. If system reboots successfully without the adapter, replace that
3.
card.
(Trained service technician only) Replace the processor.
4.
S.2018001
[S.2018001] An Uncorrected PCIe Error has Occurred at Bus % Device % Function %. The Vendor ID
for the device is % and the Device ID is %.
Explanation: PCIe Uncorrected Error Detected
Severity: Error
User response: Complete the following steps:
If this node and/or any attached cables were recently installed, moved, serviced or upgraded, a. Reseat Adapter
1.
and any attached cables. b. Reload Device Driver c. If device is not recognized, reconfiguring slot to Gen1 or
Gen2 may be required. Gen1/Gen2 settings can be configured via F1 Setup -> System Settings -> Devices and I/O
Ports -> PCIe Gen1/Gen2/Gen3 Speed Selection, or the ASU Utility.
2.
Check IBM Support website for an applicable device driver, firmware update, version of service information for
this product or other information that applies to this error. Load new device driver and any required firmware
updates.
3.
If problem persists, then remove Adapter Card. If system reboots successfully without the adapter, replace that
card.
4.
(Trained service technician only) Replace the processor.
504
System x3100 M5 Type 5457: Installation and Service Guide

Advertisement

Table of Contents
loading

Table of Contents