IBM x3100 M5 Type 5457 Installation And Service Manual page 648

Hide thumbs Also See for x3100 M5 Type 5457:
Table of Contents

Advertisement

215-801-000 • 215-802-000
215-801-000
Optical Drive Test Aborted
Explanation: Optical Drive Test Aborted. Unable to communicate with driver.
Severity: Warning
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Make sure that the DSA Diagnostic code is at the latest level.
2. Run the test again.
3. Check the drive cabling for loose or broken connections at both ends or damage to the cable. Replace the cable if
damage is present.
4. Run the test again.
5. Check system firmware level and upgrade if necessary.The installed firmware level can be found in the DSA
Diagnostic Event Log within the Firmware/VPD section for this component.
6. Run the test again.
Related Links:
IBM Support Website
v
Latest level of DSA
v
Latest level of BMC/IMM
v
215-802-000
Optical Drive Test Aborted
Explanation: Optical Drive Test Aborted. A read error was encountered.
Severity: Warning
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Insert a new CD or DVD into the drive and wait for 15 seconds for the media to be recognized. Rerun the test.
2. Check the drive cabling for loose or broken connections at both ends or damage to the cable. Replace the cable if
damage is present.
3. Run the test again.
4. If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service Guide" for the
next corrective action.
Related Links:
IBM Support Website
v
v
Latest level of DSA
Latest level of BMC/IMM
v
632
System x3100 M5 Type 5457: Installation and Service Guide